Compressed-Air Reservoir - Krone Comprima F 155 XC X-treme Original Operating Instructions

Hide thumbs Also See for Comprima F 155 XC X-treme:
Table of Contents

Advertisement

17.20.3

Compressed-air reservoir

Fig. 251
The compressed air reservoir (1) stores the compressed air that is pumped by the compressor.
Therefore condensation water may settle in the compressed air reservoir (1) during operation.
The compressed-air reservoir must be emptied regularly. Specifically, it must be emptied:
daily in winter (when being used),
otherwise weekly and
at least after 20 operating hours.
The drain valve (2) on the bottom of the compressed air reservoir (1) is used for draining.
Switch off and secure the machine
Open the drain valve and allow the condensation to run out
Check the drain valve, clean it and screw it back in
Note
If the drain valve has a heavy accumulation of dirt or is leaking, it must be replaced by a new
one.
WARNING!
Risk of injury from corroded or damaged compressed air reservoirs.
Damaged or corroded compressed air reservoirs may burst and cause serious injuries.
Observe the inspection intervals according to the maintenance table, see chapter
Maintenance Engine "Maintenance table".
Have damaged or corroded compressed air reservoirs replaced immediately by a service
centre.