1-phase Hybrids-FAQ
Operation mode description of 1-phase residential
storage inverter
Applicable to: SHxxRS series
1
Production for self-consumption
The inverter is set to the mode of production for self-consumption, and the control
supplies power to the load first (including the backup port load).
1.1 Daytime PV power ≥ load power
As shown in Figure 3-3 below, when the battery SOC is lower than 100%, after
the PV input power meets the load power supply, the remaining energy
charges the battery and still delivers the remaining energy to the power grid.
When the battery SOC is 100%, after the PV input power meets the load power
supply, the surplus electric energy is transmitted to the power grid.
© 2021 Sungrow. All rights reserved. Subject to change without notice. Version 1.1
Sungrow Deutschland GmbH | Balanstr. 59 | 81541 München |
Figure 3-3 Daytime PV power ≥ load power