7. Shutting off/Reactivating the device.
If the device is shut off and left unused for a long time, you can issue the STANDBY command (
corresponds to the command number 4 and must be issued twice to confirm the operation.
Position the
WineCapKey
in the spot indicated in
the
WineCapKey
from device.
Verify that the device asks for confirmation of STANDBY command with alternate GREEN/RED flashing, then position again the
WineCapKey
and wait for four flashes again. The device will confirm the STANDBY status lighting the RED led for 2 seconds twice.
To reactivate the device the TEST command must be issued.

8. Technical Information.

Power supply
Battery life (*)
Measures acquired
(2 input channels)
Sampling interval
*
(
)
Datalogger capacity
Working temperature
Radio frequency
Radio coverage
Sealing
Dimensions
Weight
Case material
Mounting
Connections
Cable external diameter
Copper wire section
Outdoor temperature - Transducer type
Outdoor temperature - Measure range
Outdoor temperature - Measure accuracy
Outdoor temperature - Measure resolution
CO₂ - Measure range
CO₂ - Measure accuracy
CO₂ - Measure resolution
CO₂ - Temperature dependence
CO₂ - Long term stability
CO₂ - Transducer sealing
* battery life may be influenced by fieldwork conditions, sampling interval and system configuration.
** radio coverage reachable using up to 32
CAPETTI ELETTRONICA s.r.l. - Strada Stratta, 57
10090 CASTIGLIONE TORINESE - TORINO - ITALY
VAT 04837130014 - Phone 011.981.98.11 - Fax 011.981.98.210
e-mail
info@capetti.it
Picture 3 - WineCapKey positioning
WR12 repeaters
(maximum 16 for each path) between the device and the basestation.
- web
www.capetti.it
User Manual
and wait for four AMBER flashes, then remove
2.4Ah - 3.6V type "AA" lithium internal battery
Up to 5years
(samples every 10 minutes and radio signal quality at least sufficient)
• Outdoor temperature
• CO₂
Selectable from one minute to 24 hours
128,000 samples (
for each channel
• Operative: -30°C ÷ +60°C
• Warehousing: -40°C ÷ +70°C
ISM 868MHz
Up to 6Km in line of sight
(can be extended using
WR12
battery powered repeaters)
IP65
90x120x50mm
350g
ABS
Fix on 4 points
Wireless USB
4.7mm maximum
0.05 ÷ 2.5mm² / ÷ 14 AWG
NTC10KΩ
-30°C ÷ +60°C
• ± 0.5°C Range -30°C ÷ 0°C
• ± 0.2°C Range 0°C ÷ +60°C
0.01°C
0÷2,000ppm
<±50ppm (+2% of value acquired)
1ppm
2ppm CO₂/°C typical
20ppm/year
IP54
WSD12T-CO
refer to
Picture 4 - Commands table
(10 minutes default)
)