Example Of Configurecmd - netvox R718WB2 User Manual

Wireless 2-gang water leak detector with rope sensor
Hide thumbs Also See for R718WB2:
Table of Contents

Advertisement

Device
Device
Type
R718WB2
0x47
Example of Uplink: 0147012401000000000000
1
st
byte (01): Version
nd
2
byte (47): DeviceType 0x47 - R718WB2
3
rd
byte (01): ReportType
th
4
byte (24): Battery-3.6v , 24Hex=36 Dec
th
5
byte (01): Water Leak1-Leak
6
th
byte (00): Water Leak1-No leak
th
th
7
~11
byte (0000000000): Reserved

5.2 Example of ConfigureCmd

FPort:0x07
Bytes
1
CmdID
CmdID– 1 byte
DeviceType– 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)
Description
Device
Config
ReportReq
Config
ReportRsp
R718WB2
ReadConfig
ReportReq
ReadConfig
ReportRsp
(1) Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v
Downlink: 0147003C003C0100000000
The device returns:
Report
Type
Battery
0x01
(1Byte)
unit:0.1V
1
DeviceType
Cmd
Device
ID
Type
MinTime
0x01
(2bytes Unit:s)
0x81
0x47
0x02
MinTime
0x82
(2bytes Unit:s)
NetvoxPayLoadData
WaterLeak 1
(1Byte)
0:noLeak 1:Leak
36*0.1v=3.6v
Var (Fix =9 Bytes)
NetvoxPayLoadData
NetvoxPayLoadData
MaxTime
(2bytes Unit:s)
Status
(0x00_success)
(9Bytes,Fixed 0x00)
MaxTime
(2bytes Unit:s)
6
WaterLeak 2
(1Byte)
0:noLeak 1:Leak
BatteryChange
(1byte Unit:0.1v)
(4Bytes,Fixed 0x00)
Reserved
(8Bytes,Fixed 0x00)
Reserved
BatteryChange
(1byte Unit:0.1v)
(4Bytes,Fixed 0x00)
Reserved
(5Bytes)
fixed 0x00
Reserved
Reserved

Advertisement

Table of Contents
loading

Table of Contents