Table of Contents 1. Introduction ....................2 2. Appearance ....................3 3. Features ..................... 3 4. Set Up Instruction ..................4 5. Data Report ....................5 5.1 Example of ReportDataCmd.............. 5 5.2 Example of ReportConfiguration ............7 5.3 Example of GlobalCalibrateCmd ............8 6.
R718PA1 is a Class A device based on the LoRaWAN protocol of Netvox and is compatible with the LoRaWAN protocol. R718PA1 can be connected to a corresponding carbon monoxide sensor (RS485) to report the concentration of carbon monoxide collected by the device to the corresponding gateway.
2. Appearance CO Senser Indicator Function Key Adaptor 3. Features ⚫ SX1276 wireless communication module ⚫ 12V DC power supply ⚫ CO detection ⚫ Magnetic base ⚫ Main body protection level IP65 / IP67 (optional) ⚫ Compatible with LoRaWAN Class A ⚫...
4. Set Up Instruction On/Off Power on DC12V adapter DC12V power supply, the green indicator flashing once means turn on Turn on successfully. Turn off Press and hold the function key for 5 seconds till the green indicator (Restore to factory setting) flashes 20 times.
Note: 1. The cycle of the device sending the data report is according to the default. 2. R718PA1 reports the concentration of carbon monoxide. Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://www.netvox.com.cn:8888/cmddoc to resolve uplink data.
Page 7
Uplink: 01570500FFFF0000FFFF00 byte (01): Version (57): DeviceType — R718PA1 (05): ReportType (00): Battery — 0V, DC powered – 6 — FFFF(N/A) (FFFF): O – 8 (0000): CO — 0.0ppm, 0000 (HEX) = 0 (DEC), 0* 0.1ppm = 0.0ppm – 10 (FFFF): NO —FFFF(N/A)
6. Installation 1. R718PA1 has a built-in magnet (as the figure 2. The device periodically reports the data below). It can be attached to the surface of an iron according to Max Time. The default Max object conveniently and quickly when it is installed.
7. Important Maintenance Instructions Kindly pay attention to the following in order to achieve the best maintenance of the product: •Do not put the device near or submerge into water. Minerals in rain, moisture, and other liquids could cause corrosion of electronic components. Please dry the device, if it gets wet. •Do not use or store the device in dusty or dirty environments to prevent damage to parts and electronic components.