Port 16 is switchable between Normal (MDI-X) and Uplink (MDI) positions and should be
configured according to the following guidelines:
Set the Normal/Uplink push button to the Normal position and use a straight-through cable if
the remote end of the cable is connected to an MDI-wired device such as a PC.
Set the Normal/Uplink push button to the Uplink position and use a straight-through cable if
the remote end of the cable is connected to an MDI-X device such as a 10 Mbps or 100 Mbps
hub or repeater.
For further cabling guidelines, refer to Appendix B, "Cabling Specifications."
Refer to the following illustrations for connecting to the RJ-45 ports and proceed to "Completing
and Verifying the Installation" on page 3-11.
Figure 3-2 illustrates a workstation connected to an RJ-45 port on the Model EN516 hub.
Key:
1 = Network adapter card with RJ-45 connector
2 = UTP cable to Model EN516 hub
Figure 3-2.
Connecting a workstation to an RJ-45 port on the Model EN516 hub
Note: Ethernet specifications limit segments to 328 feet (100 m) in length.