  • Page 1 Topvex TR03, TR04, TR06 Compact Air Handling Unit Installation description Corrigo ver. no. 1.2-1-00...
  • Page 2 Topvex TR03, TR04 øL 15R (½") Fig. 1 Dim. (mm) Topvex TR03 1180 1230 Topvex TR04 1480 1280 1100 Dim. (mm) ØL Weight Topvex TR03 225 kg Topvex TR04 280 kg _____________________________________________________________________________________________________ Topvex TR03, TR04, TR06 Installation description 205354 Systemair AB...
  • Page 3 Topvex TR06 1321 1700 1000 15R (½") Fig. 2 Topvex TR06: 335kg _____________________________________________________________________________________________________ Topvex TR03, TR04, TR06 Installation description 205354 Systemair AB...
  • Page 4 Description Connection Supply air Connection Extract air Connection Exhaust air Connection Outside air Supply air filter (Topvex TR04) Supply air filter (Topvex TR03, TR06) Safety switch Filter, extract air Reset button, over heat protection Connection box Heat exchanger Fan, extract air...
  • Page 5 Pump, primary circuit Fig. 5 Description Description Alarm button Connection block Alarm LED Yellow cable Write enable LED Orange cable OK button Red cable Clearing button Brown cable Mounting holes Black cable _____________________________________________________________________________________________________ Topvex TR03, TR04, TR06 Installation description 205354 Systemair AB...
  • Page 6 Emergency thermostat Overheating thermostat Frost protection temp. sensor Rotor guard Unit control Rotor motor Heat exchanger Damper outdoor air Damper exhaust air Water valve actuator NB! The dashed components are accessories. _____________________________________________________________________________________________________ Topvex TR03, TR04, TR06 Installation description 205354 Systemair AB...
  • Page 7: Electrical Connection

    Neutral, Nolla Cooling 0-10V DC DO ref Alarm output, for all alarms Alarm output, for all alarms 24V AC * These inputs may only be wired to voltage free contacts. _____________________________________________________________________________________________________ Topvex TR03, TR04, TR06 Installation description 205354 Systemair AB...
  • Page 8 Supply voltage valve actuator, Cooling Neutral Cooling 0-10V DC DO ref Alarm output, for all alarms Alarm output, for all alarms 24V AC * These inputs may only be wired to voltage free contacts _____________________________________________________________________________________________________ Topvex TR03, TR04, TR06 Installation description 205354 Systemair AB...
  • Page 9: Table Of Contents

    Introduction Installation, operation and maintenance manual concerns air handling unit type Topvex, manufactured by Systemair AB. It consists of basic information and recommendations concerning the design, installation, start-up and operation, which shall be obeyed to ensure the proper fail-free operation of the unit.
  • Page 10: Manufacturer

    Air handling units EN 50 106 Electric domestic products and similar- Topvex TR03 HW, Topvex TR03 EL Safety-Description for control of manufacture. Topvex TR04 HW, Topvex TR04 EL Topvex TR06 HW, Topvex TR06 EL Remark: EN 50 106 complies for internally wired products only.
  • Page 11: Dimension And Weight

    To obtain high efficiency, low energy consumption and the required airflow, the duct system should be commissioned for low air speeds and a low pressure drops. _____________________________________________________________________________________________________ Topvex TR03, TR04, TR06 Installation description 205354 Systemair AB...
  • Page 12: Duct Connections

    TOPVEX has electric supply through a lockable safety switch on top of the unit. All units except for Topvex TR03 HW are to be connected to a 400V 3~ alt. 230V 3~ power supply (the heater in TR03 EL can be reconnected to 230V 3~). Topvex TR03 HW needs a 230V 1~ supply. TR04 and TR06 have separate models for 230V 3~ power supply.
  • Page 13: Changing Fan Speed

    The operation of the heat exchanger is automatic and dependent on the set temperature. Heater battery TOPVEX has a built in heater battery (water or electric). The operation of the heating battery is automatic and dependent on the set temperature. _____________________________________________________________________________________________________ Topvex TR03, TR04, TR06 Installation description 205354 Systemair AB...
  • Page 14: Electrical Heater

    To pass a value without changing it, press RIGHT. To abort a change and return to the initial setting, press and hold the C-button until the cursor disappears. _____________________________________________________________________________________________________ Topvex TR03, TR04, TR06 Installation description 205354 Systemair AB...
  • Page 15: Additional Accessories

    Set present time and date, set the medium and low airflow and program the week schedule. Check that: - there is no unusual noise from the unit. - control panel and lamp signals are in function. _____________________________________________________________________________________________________ Topvex TR03, TR04, TR06 Installation description 205354 Systemair AB...
  • Page 16 NB. Systemair AB reserves the rights at any time, without prior notice, make changes and improvements to the contents of this manual. Systemair AB Industrivägen 3 SE-739 30 Skinnskatteberg Phone +46 222 440 00 Fax +46 222 440 99 www.systemair.com...