4.1.2 GUI control function
4.1.2.1 GUI control the emission
Choose the GUI control Mode
1
GUI Full Control mode(GUI Ctrl):When selecting the GUI full Control mode, all the
parameters of Internal/External Control mode (EG. power, frequency, pulse width, PA, MO) will
change to Internal Control mode. This mode will not be preserved after power off. It will change
to "Free Ctrl" mode after serial port closed, and all the parameters of Internal/External Control
mode will be changed to the previous free control mode setting. User can select this mode to test
the emission of laser temporarily.
Free Control Mode (Free Ctrl): When selecting free Control mode, user can choose parameter
control mode individually. In this mode, all the settings will be preserved after power off. EG.
User can select this mode to lock a specific frequency or output power individually when don't
want to control it by external signal.
Set parameters and emitting
2
Figure 15 GUI Full Ctrl mode
Figure 16 Free Ctrl mode