Problem/Report
Water lying on top edge of lower door
panel and/or bottom of cabinet.
Water lying in bottom of machine
Fault Diagnosis: Miscellaneous
Problem/Report
Repeating beeping
noise
No LED Control
Lights
Machine Shakes on
Start-up.
Tripping out
Electricity Supply.
Possible Cause
Overflowing Drip Tray
waste container.
Level Sensors not
working.
Leak in supply inlet pipe
work and/or filter.
Leak from machine
water pipe work fittings.
Possible Cause
Level Sensor fitted and tank
full.
No electricity to Machine.
Check Fuse in IEC Socket.
Control PCB not working
(Machine
working normally
otherwise).
Compressor Starting.
Level Surface.
Uneven Surface.
Missing Fixings.
Machine in high humidity
environment.
Electrical circuitry faults.
Suggested Action
Empty Waste Container and
check
drainpipe is not blocked.
Check operation/repair/
replace as required.
Locate and repair accordingly.
Locate and repair accordingly.
Check pressure and fit pressure
reducing valve if needed.
Suggested Action
Empty Level Sensor Tank.
Check power supply and reconnect as necessary
(Also check out other
symptoms as described separately).
Replace if necessary.
Check/replace PCB.
No action needed. This is quite normal.
Level up machine using adjustable feet.
Replace missing fixings.
Discuss possible repositioning with customer.
Test, identify and address accordingly. See
Electrical Diagrams.