The AVIA heater offers an integrated dry contact relay for
local and remote control of ON/OFF devices like pumps,
water features, valves and lights.
Auxiliary output is available in terminal P9 "AUX". Use
the supplied harness to control ON/OFF functions or
power switching.
AUX terminal can be used as direct control or as pilot
relay to a higher rating relay or power contactor.
Terminal
Common
Normally Open
Black and Red
Normally Closed
Black and White
CAUTION: Do not exceed Auxiliary relay rating. Check power
requirements of any electric component connected to this device,
following the applicable installation norms and requirements.
Wire
AC Rating
Black
250V Max,
3A
DC Rating
30V Max,
3A