3.
Battery backup outlets: These outlets provide battery backup, EMI
filtering, line conditioning, and surge protection. Battery power is
automatically provided in case of power failure.
4.
Surge-protected outlets: These outlets do not provide power during
power failure.
5.
HID USB port: Allows the UPS to appear in Windows like a battery
icon. When the power is out, you can still see the battery level and
adjust its settings. Also Windows power management options are
available. In case you need more advanced local management we
recommend you to install and use "ViewPower" software.
6.
Network, Modem or Phone surge protection: (only for Token 800
model) This UPS protects a single line (1 in/1 out) phone, modem, or
fax machine from surges when connected through the UPS.
7.
USB charger port: 5VDC, 2.1A (only for Token 800 model)
8.
AC input power cord: Connect to utility power.
9.
Input circuit breaker: The circuit breaker provides optimal overload
protection.

Important safety warnings

3
Please comply with all warnings and operating instructions in this manual
strictly. Save this manual properly and carefully read the following
instructions before installing the unit. Do not operate this unit before
reading through all safety information and operating instructions
carefully:
Transportation
• Please transport the UPS system only in the original package to
protect against shock and impact.
Preparation
• Condensation may occur if the UPS system is moved directly from
cold to warm environment. The UPS system must be absolutely dry
before being installed. Please allow at least two hours for the UPS
system to acclimate to the environment.
• Do not install the UPS system near water or in moist environments.