15.2 Time settings
Exact time setting can be adjusted in both operation modes (working and standby mode). Press on
button
once, the display shows the next situation:
Hour position "00" starts to blink and with
and
buttons, the hour value can be set. Then we press the
button and minutes "00" starts to blink.
Now with
and
buttons set current minutes value.
15.3 Setting timer for heating
Sanitary water can be heated in two ways. The most common heating of sanitary water is in relation to the need
for it. Whenever the temperature of water in the tank falls for the temperature difference (Parameter no. 1)
below the set point (Parameter no. 2) the device turns on and heats up the sanitary water.
In the second way, the unit will heat up sanitary water by a scheduled program. The regulator allows the setting
of two working and two static cycles. The device can only heat up the water in the active cycle's time. If the
temperature of domestic hot water during the sleep cycle falls below the temperature difference, the heat pump
will not start. This operation mode is effective in case of two tariff counter and setting for the operation in the
lower rate, but may occasionally cause a lack of domestic hot water in case of short work time interval.
15