11 UNIT INSTALLATION

Minimal space requirements for installation and maintenance:
Air direction
The unit must always be installed in a vertical position. We recommend that the unit is inclined 2-3° backwards to
enable smoother condensate runoff.
WARNING!
After placing the unit in its final location, wait at least 1 hour before turning the unit on.
WARNING!
In case of service intervention and if minimum clearances are disregarded, the user covers the costs
incurred.
Min. one elbow is required. Because the inlet and outlet air connections are very close together, there is a
possibility of cold air recirculation, the device will go to defrost mode more often.
WARNING!
Good insulation of neighboring walls is advisable.
Installation possibilities:
WARNING!
Maximal length of air ducts is 10m. Each bend 90°reduces the maximal length for 1 m. All air duct pipes need
to be insulated to prevent condensation. Never reduce the internal diameter of the pipe.
Air direction
50
When the air inlet and outlet are in a
different space, each space needs to have
an opening to the outside or they need to
be connected with an opening surface at
2
least 300mm
pressure.
8
20
to be able to equalize