12.1 Solar collector installation

STT: solar temp. sensor
EV: solar expansion vessel
FS: flow limiter with flow meter
HW: hot water outlet
The solar system must be connected to connections marked with »B« and »D« on scheme »10. Unit dimensions«.
Regulation of the solar system must be connected to a separate regulation system for regulating the solar
circulation pump. The temperature sensor for the water temperature can be inserted into the sleeve next to the
heat pump temperature sensor for the bottom temperature, which is located on the back side of the heat pump.
The maximum allowed temperature of water from the solar system must never exceed 85°C. This needs to be
considered when setting the parameters for the solar system. The maximum pressure of 0,5MPa must also never
be exceeded.
WARNING!
Failure to abide with the above instructions can lead to device malfunction or failure. In this case rights under
warranty are lost.
STT
2X0,75 mm2
2X0,75 mm2
SR
FS
3X1,5 mm2
P
EV
SV
P: solar circulation pump
SV: safety pressure valve
SV: electronic safety valve
DR: drainage
10