HP HPE D6020 Installation Manual page 33

Disk enclosure
Hide thumbs Also See for HPE D6020:
Table of Contents

Advertisement

Code
Issue
BD
ESP communication error
BE
Incompatible firmware in local
ESP
BF
Incomplete system identification
C1
Permanent error in temperature
sensor I2C bus
C2
Error reading data from
temperature sensor
C3
Warning temperature reached in
temperature sensor.
C4
Critical temperature reached in
temperature sensor
C5
Minimum temperature reached in
temperature sensor
C6
Fans commanded to maximum
speed
C7
System shutdown - over
temperature
C8
Permanent error in partner I/O
module temperature sensor I2C
bus
CA
Solution NVRAM tag error
CB
Solution NVRAM checksum error
CC
Manufacturing NVRAM tag error
Possible solution
Wait at least 5 minutes.
Reseat the I/O module.
Replace the I/O module.
Verify that the storage enclosure processor (SEP) firmware is
correct and that the same firmware is installed on both I/O
modules.
Wait at least 5 minutes.
Reseat the I/O module.
Replace the I/O module.
Restore system identification NVRAMs, and reboot the I/O
module (reseat it).
Reseat the I/O module.
Replace the I/O module.
Reseat the I/O module.
Replace the I/O module.
Verify if the environment is temperature-compliant.
Verify if the environment is temperature-compliant.
Verify if the environment is temperature compliant.
Verify if the environment is temperature-compliant.
Verify if the environment is temperature-compliant.
Power on the enclosure.
Reseat the primary I/O module.
Reseat the secondary I/O module.
Replace the I/O module.
Replace the I/O module.
Replace the I/O module.
Table Continued
33
Troubleshooting