Motor Lead Harness (Mx-85 & 140 Only) - Flowserve Limitorque Accutronix MX Maintenance & Spare Parts Manual

Hide thumbs Also See for Limitorque Accutronix MX:
Table of Contents

Advertisement

Electronic Assemblies
STEP 4
Using a 3 mm hex key, fit the M4 screw (#14-8) into the
actuator housing to secure the encoder cartridge.
5.8 Motor Lead Harness
(MX-85 & 140 Only)
Figure 5.17 – Motor Lead Assembly
TO MOTOR
6 PIN, AMP PLUG
1
2
3
4
5
6
5-32
T3
T2
T1
Th
Th
Accutronix MX Maintenance & Spare Parts Manual
4
SEAL
Flow Control Division
Limitorque Actuation Systems
TO CONTRACTOR
2 PIN, AMP PLUG
T3
1
2
T2
TO CONTRACTOR
2 PIN, AMP CAP
1
T1
2
Th
4
2
Th
TO MAIN PROCESSOR BOARD
Molex 4 PIN
MOLEX RECEPTACLE
130-12000 Revision B • November 2002
(P4)