Remove Actuator from Mounting Adapter
3.1.2 Remounting (Type B1/B4/B4E Base)
STEP 3
Ensure stem nut (#1-22) is secured inside actuator drive sleeve with
retaining ring (#1-23). Lower actuator onto the mating component,
making sure to align stem nut key and keyway with mating
component.
STEP 4
Ensure that the actuator and mounting adapter flange
mating holes are aligned correctly.
STEP 5
a
WARNING
incoming power leads L1, L2, L3, and control wiring in the terminal block.
Secure the actuator to the mounting adapter with
mounting bolts.
STEP 6
Reconnect incoming power leads L1, L2, L3, and control
wiring to the terminal block. Restore power source when
ready for operation.
3-2
: Hazardous Voltage! Turn off all power sources before rewiring
Accutronix MX Maintenance & Spare Parts Manual