El.Mo FXPRO User Manual

El.Mo FXPRO User Manual

Analogue-addressable fire control unit, with integrated power supply unit and control panel

Advertisement

Quick Links

FXPRO
Analogue-addressable fire control
unit, with integrated power supply
unit and control panel
090010929
Declaration of performance
nº 0051 – CPR – 0455
Standards
15
EN54-2:2007, EN54-4:2007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FXPRO and is the answer not in the manual?

Questions and answers

Summary of Contents for El.Mo FXPRO

  • Page 1 FXPRO Analogue-addressable fire control unit, with integrated power supply unit and control panel 090010929 Declaration of performance nº 0051 – CPR – 0455 Standards EN54-2:2007, EN54-4:2007...
  • Page 2 (explosion and fire). EU DECLARATION OF CONFORMITY FXPRO control units comply with current European EMC and LVD directives. The full text of the EU declaration of conformity is available at the following Internet address: elmospa.com – registration is quick and easy.
  • Page 3: Introduction

    090010929 - USER MANUAL - FXPRO 1. INTRODUCTION FXPRO is a fire control unit which integrated control panel can command every unit in the network. This manual explains how to use the FXPRO fire control unit. It is part of the technical documentation of the unit, together with the technical manual, the programming manual and the quick guide.
  • Page 4 ¹While in StandAlone mode (the “Select which U you want to connect to” screen does not appear when pressing Selected unit), these LEDs only show the status of the FXPRO panel and all other Unit group LEDs are turned OFF. — ²Call the maintenance technician.
  • Page 5: Front Panel Browsing

    • key in * or 0 (confirm with ENT) to access the panel’s pages. If FXPRO is the only unit of the network, the installer can disable this choice screen: press Selected unit to switch from the screens of FXPRO (assigned to the U1 LED column) to those of the control panel and back again.
  • Page 6: User Identification And Lowering The Access Level

    FXPRO - USER MANUAL - 090010929 3.2.1 User identification and lowering the access level The L2 password of each user is a personal identification number (PIN) which usage is saved in the events log, allowing to trace who gave each command. To avoid unauthorized users using the password-protected menus after a password has been used, always manually lower the access level: •...
  • Page 7: Panel Usage

    090010929 - USER MANUAL - FXPRO 4. PANEL USAGE Welcome screen WELCOME FX PRO Works from Works from Works from any panel any level 1 any panel Press ESC screen emulated screen screen Insert password Select which U you Silences this...
  • Page 8: Panel Screens System Messages

    5. UNIT USAGE This chapter details the contents of the menus of FXPRO and the procedures that are needed to manage the fire detection system. Other units in the same network can be managed by emulating them through FXPRO’s frontal panel, using the selected unit button and following their user manual.
  • Page 9: Delayed Mode

    090010929 - USER MANUAL - FXPRO 5.1.3 Delayed mode The contents of this chapter are only valid if d . 6.2.4), is enabled and only during the time slots set while elayed mode chaP programming the unit and marked on the last page of this manual.
  • Page 10: Unit Screens System Messages

    FXPRO - USER MANUAL - 090010929 5.3 Unit screens system messages When there are active alarm or fault events, the main screen changes to show some which L1-DEVICE FAULT Z004 loop, address and zone generated those events. ADDRESS TEXT -A013 •...
  • Page 11: User Menu

    090010929 - USER MANUAL - FXPRO 6. USER MENU The Program entry allows access to the programming menu, protected by a L3 password. Press ESC to exit the password request screen. ¤ 6.1 Test The Test LED will glow while the functions of this menu are active.
  • Page 12: Device

    FXPRO - USER MANUAL - 090010929 6.2.2 Device A disabled device generates no alarm or fault events and never activates, but it keeps sending L1A001 its analogue value during the polling (the cyclical interrogation of all addresses made by the >L1A002...
  • Page 13: Events

    090010929 - USER MANUAL - FXPRO ¤ 6.3.3 Events This function lets you look at the events log of a unit, which is the list of all the system events 02/01/15 18:55 that occurred on the unit since the first one (the system reset). The log holds up to 4000...
  • Page 14: Print

    FXPRO - USER MANUAL - 090010929 6.4 Print 6.4.1 Mode Use -> and <- to choose a functioning mode for the printer, press ENT to confirm. MODE • Offline (default): the printer is inactive. -> OFFLINE • Events log: print events as soon as they happen.
  • Page 15: Device Features

    090010929 - USER MANUAL - FXPRO 7. DEVICE FEATURES This list, containing all AS, FXLOOP and Evolution devices currently available, is not final. FXLOOP Used AS devices Evolution devices Address type (in order) devices addresses 1IASBOBX Input Module 4IASBOX 4 Input Modules...
  • Page 16: System Events Table

    FXPRO - USER MANUAL - 090010929 8. SYSTEM EVENTS TABLE System events are displayed in the system messages and are saved to the events log. Their class and origin can be used to filter events for log visualization or printing purposes.
  • Page 17: Central Booklet

    090010929 - USER MANUAL - FXPRO 9. CENTRAL BOOKLET Copy according to your needs. File in two copies, one for the installer and one for archive. Installing company: Address: Telephone number: Installer engineer: Telephone number: Installation date: Action # Date / time...
  • Page 18: Table Of Contents

    FXPRO - USER MANUAL - 090010929 10. SUMMARY 1. INTRODUCTION ................3 1.1 Definitions.
  • Page 19: Notes

    090010929 - USER MANUAL - FXPRO 11. NOTES international@elmospa.com elmospa.com...
  • Page 20: Data Set By The Installer

    ______ line* *Do never disable the bell outputs marked on the table. FXPRO - Analogue-addressable fire control unit, with integrated power supply unit and control panel USER MANUAL - June 2017 edition 090010929 Product specifications as described above do not bind the manufacturer and may be altered without prior notice.