Chapter 4: Test Setup and Testing
FAST RE-SELECT THRESHOLD: 10 dB
SLOW RE-SELECT HYSTERESIS: 10 dB
FAST RE-SELECT HYSTERESIS: 10 dB
23 Press Return.
24 Press Trunk Type → message Trunked (Transmission).
25 Press More.
NOTICE: The displayed values are factory defaults and should not be changed. It is not
required to configure Call Types, Call Arial, and Messages.
26 Press More.
4.7

Configuring IFR 3901/IFR 3902/IFR 3920 Manual Screen Test

Use these procedures to configure the IFR 3901/IFR 3902/IFR 3920 manual screen test.
Procedure:
1 Press TEST → TAB.
2 Enter 3600 for Control Channel.
3 Enter 3700 for Traffic Channel.
4 Enter 3 for Slot.
5 Enter -75 for RF Gen Level.
6 Select Expected → 30.0 dBm/1 W for Mobile Power.
7 To select Tx Measurements, press TAB.
8 Press Normal for Burst.
The test equipment configuration setup is completed.
NOTICE: The System Setup Configuration Data is saved even after the power is turned off.
However, the Manual Test Setup is not saved.
4.8

Configuring IFR 2968 Manual Screen Test

Use these procedures to configure the IFR 2968 manual screen test.
Procedure:
1 Press Manual to enter the Manual Test screen.
2 Press Control Channel. Enter 3605 and press Control Channel.
(IFR 3605 = Rx 390.125000 MHz)
3 Press Traffic Channel. Enter 3605 and press Traffic Channel.
The marker goes to Timeslot.
4 Enter 3 and press Traffic Channel.
NOTICE: The Traffic Channel number changes automatically after entering the Control
Channel number.
5 Press RF Gen Level. Enter -75 and press dBm → RF Gen Level.
6 Press Mobile Power. Enter 30 dBm/1 W.