Trane S9V2B040U3PSBB Installer's Manual page 33

Upflow/horizontal and dedicated downflow gas-fired, direct/non-direct vent, 2–stage condensing variable speed furnaces
Table of Contents

Advertisement

COMBUSTIBLE MATERIAL WALL
A minimum clearance of 1" to combustible materials must be
maintained when using single wall stainless steel venting.
Shield material to be a minimum of 24 gauge stainless or aluminized
sheet metal. Minimum dimensions are 12"x12". Shield must be
fastened to both inside and outside of wall. Use screws or anchor type
fasteners suited to the outside or inside wall surfaces.
NONCOMBUSTIBLE MATERIAL WALL
The hole through the wall must be large enough to maintain pitch of
vent and properly seal.
Use cement mortar seal on inside and outside of wall.
18-CE01D1-1M-EN
F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n
COUPLING
(PLASTIC
STUD
VENTING)
6 IN. MIN.
(TO JOINT)
1" CLEARANCE
(AIR SPACE)
VENTING THROUGH COMBUSTIBLE WALLS
Pitch - 1/4 Inch Per Foot
CLEARANCE (0" ACCEPTABLE FOR PVC VENT PIPE)
(1" ACCEPTABLE FOR TYPE 29-4C STAINLESS STEEL VENT PIPE)
COUPLING
(PLASTIC
VENTING)
6 IN. MIN.
(TO JOINT)
CEMENT
MORTAR SEAL
INSIDE &
OUTSIDE
VENTING THROUGH NON-COMBUSTIBLE WALLS
Pitch - 1/4 Inch Per Foot
PVC WALL
MOUNT FLANGE
(OPTIONAL)
APPROVED
TERMINATION
12" MINIMUM ABOVE
NORMALLY EXPECTED
SNOW ACCUMULATION
LEVEL
PVC WALL
MOUNT FLANGE
(OPTIONAL)
APPROVED
TERMINATION
12" MINIMUM ABOVE
NORMALLY EXPECTED
SNOW ACCUMULATION
LEVEL