2.1 Intended Use

The Sunny Central is a PV inverter which converts the direct current generated in the PV modules into grid-compliant
alternating current. An external MV transformer fitted downstream feeds the generated alternating current into the utility
grid.
The Sunny Central is suitable for outdoor installation provided that the specified safety distances are maintained. The
Sunny Central for station installation is suitable exclusively for indoor installation provided that the specified safety
distances are maintained. The enclosure conforms with degree of protection IP54. The Sunny Central is classified under
Class 4C2 as per EN 60721-3-4 and is suitable for operation in a chemically active environment.
The maximum permissible DC input voltage of the Sunny Central must not be exceeded.
The Sunny Central must only be operated in conjunction with a suitable MV transformer. The MV transformer must be
designed for voltages that arise during pulsed mode of the Sunny Central. The maximum AC voltages can reach the
following magnitudes to ground:
• For inverter types SC 500CP XT/630CP XT/720CP XT/760CP XT/800CP XT, voltages can reach a maximum of
±1,450 V to ground.
• For inverter type SC 850CP XT / 900CP XT, voltages can reach a maximum of ±1,600 V to ground.
You will find further information in the Technical Information "Medium-Voltage Transformer - Important Requirements for
Medium-Voltage Transformers and Transformers for Auxiliary Power Supply for SUNNY CENTRAL Inverters of the CP XT
and CP-JP Production Series" at www.SMA-Solar.com.
Do not switch off or adjust settings that affect grid management services without first obtaining approval from the grid
operator.
Only use the product in accordance with the information provided in the enclosed documentation. Any other application
may cause personal injury or property damage.
Only persons fulfilling all of the skills for the target group are permitted to work on or with the Sunny Central.
Alterations to the product, e.g. modifications or conversions, are only permitted with the express written permission of
SMA Solar Technology AG. Making unauthorized changes will void the warranty and warranty claims and will normally
result in invalidation of the operating permit. SMA Solar Technology AG shall not be held liable for any damage caused
by such changes.
All work on the Sunny Central must be performed using appropriate tools and in compliance with the ESD protection
regulations.
Suitable personal protective equipment is to be worn by all persons working on or with the Sunny Central.
Unauthorized persons must not operate the Sunny Central and must be kept at a safe distance from the Sunny Central.
The Sunny Central must not be operated with its doors open.
The Sunny Central must not be opened when it is raining or when humidity exceeds 95%.
The Sunny Central must not be operated with any technical defects.
The enclosed documentation is an integral part of this product. Keep the documentation in a convenient place for future
reference and observe all instructions contained therein.
Any use of the Sunny Central other than that described in the Intended Use section is not deemed to be intended use.
8