6. Technical Parameters
Power supply
•
Voltage:
100–240 V AC
•
Frequency: 50/50 Hz
•
Supply output:
•
65 W version with support for 2 Cabin switches (2x CS)
•
120 W version with support for 4 Cabin switches (4x CS)
Power supply backup
•
12 V / 9 Ah internal gel-lead-acid accumulator
•
optional connection of an external higher-capacity gel-lead-acid accumulator
User interface
•
Control: web interface
•
Default ID/Password: admin/2n
•
Device State Indicator: refer
Antenna
•
Impedance: 50 Ω
•
2x SMA connector (for main / optional antenna)
DSL (Cabin switch line):
•
48 V / 1 A version with support for 2 Cabin switches (Cabin switch 1&2)
•
48 V / 1 A version with support for 4 Cabin switches (Cabin switch 3&4)
I/O
•
INP:
•
pin1: 10.5 V 5 mA
•
pin2: input 1 – 47 kOhm serial resistor, < 2 V = LOW, > 4 V = HIGH, 30 V DC max
•
pin3: input 2 – 47 kOhm serial resistor, < 2 V = LOW, > 4 V = HIGH, 30 V DC max
•
pin4: GND
•
REL:
•
Contact resistance: 75 mOhm 1 A, 6 V DC
•
Operational contact parameters: 30 V / 1 A DC
•
Max allowed contact current: 2 A
•
Pin 1–2 (4–5): closed at relax (NC)
•
Pin 2–3 (5–6): open at relax (NC)
Frequency bands
•
EU version:
•
LTE FDD: B1/B3/B5/B7/B8/B20
•
LTE TDD: B38/B40/B41
•
WCDMA: B1/B5/B8
•
GSM: B3/B