Power supply 
Voltage:
100–240 V AC
Frequency: 50/50 Hz
Supply output:
65 W version with support for 2 Cabin switches (2x CS)
120 W version with support for 4 Cabin switches (4x CS)
Power supply backup
12 V / 9 Ah internal gel-lead-acid accumulator 
optional connection of an external higher-capacity gel-lead-acid accumulator
User interface
Control: web interface
Default ID/Password: admin/2n
Device State Indicator: refer
Antenna
Impedance: 50 Ω
2x SMA connector (for main / optional antenna)
DSL (Cabin switch line): 
48 V / 1 A version with support for 2 Cabin switches (Cabin switch 1&2)
48 V / 1 A version with support for 4 Cabin switches (Cabin switch 3&4)
I/O
INP:
pin1: 10.5 V 5 mA
pin2:  input 1 – 47 kOhm serial resistor, < 2 V = LOW,  > 4 V = HIGH, 30 V DC max
pin3:  input 2 – 47 kOhm serial resistor, < 2 V = LOW,  > 4 V = HIGH, 30 V DC max
pin4: GND
REL:
Contact resistance: 75 mOhm 1 A, 6 V DC
Operational contact parameters: 30 V / 1 A DC
Max allowed contact current: 2 A
Pin 1–2 (4–5): closed at relax (NC)
Pin 2–3 (5–6): open at relax (NC)
Frequency bands
EU version:
LTE FDD: B1/B3/B5/B7/B8/B20
LTE TDD: B38/B40/B41
WCDMA: B1/B5/B8
GSM: B3/B