DSL voltage – DSL module supply voltage (10.5 V).
Line 1 voltage / current – line 1 voltage and current (48 V, 1 A max, recommended: up to
0.7 A).
Line 2 voltage / current – line 2 voltage and current (48 V, 1 A max, recommended: up to
0.7 A).

3.1.3.1 External Battery Connection

Use a 1.5 mm
wire of the maximum length of 1 m for external battery connection. Thread the
cable through the mains cable bushing using the larger hole. Maintain polarity while connecting
the battery. 
Caution
Make an incision in the silicone bushing as indicated to insert a cable.
If the external battery is not connected, use a plastic blind to close the mains cable
threading hole.

3.1.4 Input and Output Pins

The Input / Output Pins tab shows the states of the device logic inputs and outputs.
Input 1 – 0 means that the input is deactivated (voltage below 2 V), 1 means that the IN1
input is activated (voltage above 4 V).
Input 2 – 0 means that the input is deactivated (voltage below 2 V), 1 means that the IN2
input is activated (voltage above 4 V).
Output 1 – 0 means that the relay is open (connected pins 1 and 2), 1 means that REL1 is
closed (connected pins 2 and 3).
Output 2 – 0 means that the relay is open (connected pins 4 and 5), 1 means that REL2 is
closed (connected pins 5 and 6).