Brymen BM2807CSE Series User Manual page 19

Enhanced practical multimeter series
Table of Contents

Advertisement

BeepJack
audible & visible input warning
TM
Electrical Specification
Accuracy is given as ± (% of reading digits + number of digits) or otherwise specified
@ 23°C ± 5°C
AC Voltage & Current accuracies are specified from 1 % to 100 % of range or
otherwise specified. Maximum Crest Factor <2:1 at full scale & <4:1 at half scale, and
with signal component frequencies limited to the specified bandwidth of the AC
functions for non-sinusoidal waveforms
AC Voltage
RANGE
50Hz ~ 60Hz
60.00mV
, 600.0mV
1)
6.000V, 60.00V, 600.0V, 1000V
45Hz ~ 500Hz
60.00mV
, 600.0mV
1)
6.000V, 60.00V, 600.0V, 1000V
500Hz ~ 1kHz
60.00mV
, 600.0mV
1)
6.000V, 60.00V, 600.0V, 1000V
Input Impedance: 10M, 20pF nominal
Signal peak absolute values, including DC bias, less than 130mV
1)
Signal peak absolute values, including DC bias, less than 1300mV
2)
VFD-ACV (with Low Pass Filter )
RANGE
10 ~ 100Hz
600.0V, 1000V
100 ~ 400Hz
600.0V, 1000V
Not specified for fundamental frequency > 400Hz
1)
Accuracy linearly decreases from 1% + 3d @100Hz to 10% + 3d @400Hz
2)
2)
2)
2)
Accuracy
1.0% + 3d
0.7% + 3d
2.0% + 3d
2.0% + 3d
2.0% + 3d
Unspecified
peak
peak
Accuracy
1)
1.0% + 3d
10.0% + 3d
2)