H. Tube Channel
Service Part: SRV7095-016
Removing Tube Channel Assembly
1. Remove the 3 right side bricks.
2. Remove the baffle protection channel by bending back
the tabs using needle nose pliers located at the right and
left side of the protection cover. Lift the cover up slightly
and pull toward the front and out of the firebox (Figure
5.10).
Bend Back Tabs
Figure 5.10
3. Locate the 2 channel nuts and two bolts inside of
chamber and remove using a 7/16 socket wrench for the
nuts and a 3/8 socket wrench for the bolts (Figure 5.11).
Use 7/16 Socket Wrench
and Remove Channel Nuts
Figure 5.11
NOTE: Soak the bolts with penetrating oil for at least 15
minutes before trying to remove them.
24
Baffle Protection
Channel
Quadrafire • Expedition II AU Owner's Manual_Rev B • 2020 - ___ • 03/21
4. Slide the tube channel assembly all the way to left until
it is off the threads. Drop the right side down, then slide
the assembly back to right (Figure 5.12).
5. The ceramic blanket and both baffle boards can be
removed at the same time you remove the tube channel
assembly.
6. When the tube channel assembly is free of the left side
support, rotate clockwise and pull assembly, blanket and
baffles out through the front opening.
7. Re-install in reverse order.
2 Tube
Channel Nuts
2 Tube
Tube
Channel Bolts
Channel
Assembly
Figure 5.12
1
3
4
Rotate and
remove from
firebox
Ceramic
Blanket
Baffle
Protection Channel
2 Baffle
Boards
7095-819