e - Positioning of mouldings flat on the table:
In order to use this method to cut with precision crown mouldings for inner and external right - angled
corners, lay the moulding with its broadest backside flat on the table, pressed against the stop.
When setting up the bias and mitre angles and the tab for double mitre cuts, remember that the settings are
interdependent: when you change an angle, the other is modified.
The angles for crown mouldings are very precise and difficult to adjust. Given that the angles tend to go out
of adjustment, all settings should first be tested on scrap mouldings. In addition, most walls are not exactly
perpendicular, so adjustments should be made accordingly.
10 - Maintenance/Service
a. General maintenance:
Remove the plug from the power outlet before performing any adjustment or
maintenance.
This machine does not require special mechanical maintenance, such as the lubrication of the bearings.
Remember to keep your machine in clean condition to avoid any risk of failure.
Lubricate regularly all parts requiring it, as the shaft for instance.
Remove regularly sawing dust from the housing and protective casings.
Periodically check the power cable and, if it is damaged, replace it with an identical cable.
Having this operation performed by the After - Sales Service is advisable.
Periodically check the power cable extension cords and replace them if they are damaged.
The use of extension cords leads to a loss of power.
To limit the power loss to a minimum and prevent the tool overheating, use an extension cord with sufficient
calibre to carry the necessary current to the tool.
If the power cord is damaged, it should be replaced by the After - Sales Service to work safely.
If the power cord is damaged, unplug it immediately.
The cleaning of plastic parts should be performed when the machine is turned off, using a soft, damp cloth
and mild soap.
Do not use solvents to clean plastic parts.
Most plastics may be damaged by the solvents commercially available.
Never immerse the machine and do not use detergent, alcohol, gasoline, etc.
The blades should be stored and handled with care.
Replace the blade as soon as it shows signs of wear.
In case of problems or for a thorough cleaning, consult the After - Sales Service.
b. Brush replacement:
CAUTION!
Remember to
check and
replace the
brushes
periodically.
Check periodically the condition of the brushes. They should be
replaced when the carbon length is about 5mm. Brushes should always
be replaced in pairs. Always keep brushes clean and free to move in
the brush holder.
For their replacement or inspection: remove the threaded plugs using a
flat - head screwdriver, replace the brushes, making sure of inserting
properly the new brushes and ensuring that they slide properly in their
housing, replace the plugs, taking care not to pinch the spring - loaded
brushes.