Setting
Multicode Scan
Preferred
Symbology
Settings

Imager Settings

You should not need to modify the Imager Settings. The Override Recommended
Values setting is disabled by default. The recommended Imager Settings are
designed to work in a wide range of environments and should only be modified if
you have an advanced understanding of imagers.

Trigger Settings

Use the Trigger Settings to configure how the scan buttons work.
CK65 Mobile Computer User Guide
Description
When you enable Multicode Scan, each barcode is checked to see
whether it satisfies the defined multicode rules before the results
are transmitted. Options include:
Enable or disable multicode scanning.
Set the number of barcodes.
Specify a separator to be used between barcodes.
Define up to 10 barcodes to be included in the multicode.
Set a timeout in milliseconds. If set with a non-zero value,
the timeout starts after the scan button is pressed. Once
the timeout occurs, scanning will return to standard
(single) barcode mode.
Enable or disable the transmission of an incomplete
multicode. When enabled, the incomplete multicode is
transmitted when the incomplete transmission timeout
expires.
Set a timeout in milliseconds to use when incomplete
transmission is enabled. If set with a non-zero value, the
timeout starts after the scan button is pressed. Once the
timeout occurs, the results that were collected before the
timeout happened will be transmitted if they satisfy the
defined multicode rules.
Set the priority level (High or Low) for symbology codes. This is
used when you want to specify one symbology as a higher priority
over other symbologies in situations where both barcode
symbologies appear on the same label, but the lower priority
symbology cannot be disabled. If a code is set as a High Priority,
the decode of that symbology is accepted immediately. If a code is
set as a Low Priority, the decode is buffered to see if a decode of a
preferred High Priority symbology can be found within a given
timeout period.
To apply Preferred Symbology Settings, tap the check box.
Preferred Timeout (ms) - The amount of time milliseconds that will
allow the scanner to search for a High Priority barcode after a Low
Priority barcode has been encountered. The default is 500ms.
To set the priority level for a symbology, tap the code in the list then
select the priority. The default for all codes is "High Priority."