3.4.
Grid Charge - Specifies when to use the grid to charge the battery. If left unticked, Energizer Homepower
will not charge from the grid.
a. E.g. 20% @ 5am - 7am - Following this instruction, the battery will charge from the grid at 720W
between the times of 5am and 7am.
When used: Designate when to charge the battery, normally during off peak periods.
This allows customers to reduce the need to consume grid power during peak periods.
3.5.
PV Charge - Limits the amount of solar generation used to charge the battery(e.g. 50% @ 10am - 12pm).
a. E.g. 50% @ 10am - 12pm - With these instructions, during 5pm - 9pm, only 2160W will be available
for use from the battery. If any additional power is required, it will be drawn from the grid.
When used: Generally used to exempt scheduled periods of time from using the battery
or ensure availability of battery power by minimising consumption throughout the day.
E.g. When heat pumps are scheduled to be on during off peak periods.
3.6.
Discharge to loads - Restricts how much energy is drawn from the battery during times when site loads
are greater than solar generation. Usually, early mornings and in the evenings.
a. E.g. 60% @ 5pm - 9pm - With these instructions, during 5pm - 9pm, only 2160W will be available for
use from the battery. If any additional power is required, it will be drawn from the grid.
When used: Generally used to exempt scheduled periods of time from using the battery
or ensure availability of battery power by minimising consumption throughout the day.
E.g. When heat pumps are scheduled to be on during off peak periods.
V23-00220
6
Energizer Homepower HP-
Series - Installation Manual
10
© Energizer 2022
6
Energizer Homepower HP-
Series - Installation Manual

Specifications

BATTERY
MODULE
BM
16x LFP Cells
(Lithium Iron Phosphate)
(Battery ManaRement bystem)
Fig. 3. Block Diagram – Energizer Homepower HP-6M (Main Unit)

Electrical Specifications

Homepower Series
HP-6M
6.14
Rated Energy
1
(kWh)
5.8
Usable Capacity
2
(kWh)
Rated Capacity (Ah)
120
Dimensions (H/W/D; mm)
1244/420/183
1244/646/183
Weight (kg)
98.5
Ingress Protection
OTR
(Operating
4
Temperature Range)
Recommended Temperature
Protection Class
Operating Altitude Range
Operating Humidity (RH)
Mains Connection
Cooling
AS 62040.1:2019, AS/NZS 4777.2:2020, IEC 62619:2017, UN 38.3,
Certification & Standards
IEC 62109-1:2010, IEC 62109-2:2011, IEC 62477-1:2012,
IEC 62477-1:2012/AMD1:2016, IEC 61000-2/-3
Anti-Islanding, Over Current, Short Circuit,
Types of Protection
Over Voltage & High/Low Temperature
Country of Manufacture
V23-00220
Noark Battery Isolator (DC)
L
BACfUP
COMBINED
N
INVERTER
&
BATTERY
L
GRID
OUTPUT
N
L
N
E
L
N
BACfUP
GRID
HP-6M/1S
HP-6M/2S
HP-6M/3S
12.28
18.42
24.56
11.6
17.4
23.2
240
360
480
1244/872/183
1244/1098/183
1244/222/183
168.5
238.5
308.5
IP65
Charge: 0 to 45 °C,
Discharge: -20 to 50 °C
0 to 30 °C
Class I
<2000 m
0 - 95%
Single-phase, L/N/PE
Natural Convection
IEC 62619:2017,
UN 38.3, AS
62040.1:2019,
IEC61000-2/-3
Over Current,
Short Circuit, Over
Voltage & High/Low
Temperature
China
11
© Energizer 2022
HP-6S
3
6.14
5.8
120
70.0
N/A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Homepower hp-6m

Table of Contents