Warnings

During installation and usage, always keep the Energizer Homepower HP-6 Series units in an upright
position. Do not impact, pull, drag, step or apply strong force on the Energizer Homepower HP-6
Series units.
To help prevent damage, leave the Energizer Homepower HP-6 Series units in their original shipping
packaging, until they are ready to be installed.
Install the Energizer Homepower HP-6 Series system only on a suitable wall, using the wall-mount
bracket supplied with the product.
Before installing or using the Energizer Homepower HP-6 Series system, read all instructions and
cautionary markings included in the technical description and on the equipment.
Do not install more than three (3) Energizer Homepower HP-6S (Sub Units) in a 25A AC
branch circuit.
Do not sit on, step on, place objects on or insert objects into the Energizer Homepower HP-6M
Series units. Please refrain from placing liquids or containers (with liquids) on top of Energizer
Homepower HP-6 Series units.
Damage to the Energizer Homepower HP-6 Series units can occur from over-discharge. While in
storage, it is expected to discharge gradually. Ensure that the Energizer Homepower HP-6 Series
units are installed by the "Must Energize by Date" located on the packaging.
If an Energizer Homepower HP-6 Series unit needs to be replaced or removed, it must be turned off
as per the recommended shutdown procedure prior to removal.
Ensure the absence of any water sources above or near Energizer Homepower HP-6 Series units,
including sprinklers, water jets, garden hoses or faucets.
V23-00220
6
Energizer Homepower HP-
Series - Installation Manual
6
© Energizer 2022
6
Energizer Homepower HP-
Series - Installation Manual
2. Energizer Homepower HP-6 Series (HP-6M/HP-6S)
The Energizer Homepower HP-6 Series is an AC coupled, lithium iron phosphate based Battery Energy Storage
system (BESS), designed to operate seamlessly with existing solar (PV) installations. It is easy to install and allows
a high degree of customisation to suit a variety of energy considerations. The Energizer Homepower HP-6 Series is
modular and consists of the Main Unit (HP-6M) and optional Sub Units (HP-6S).
The Energizer Homepower HP-6 Series system measures solar generation & energy consumption using its
production & consumption CTs, and then utilises its intelligent algorithms to either charge or discharge its
batteries to reduce consumption from the grid and increase local energy usage. This improves overall energy
efficiency by aiding local consumption of solar energy and reducing export to the utility grid.
BATTERY
& BMS
ELECTRICAL CONNECTION ZONE
BATTERY
HP-6S
(SUB UNIT)
Fig. 1. Energizer Homepower HP-6M & HP-6S Units
The Energizer Homepower Installer App & web-based monitoring platform allow for comprehensive monitoring
& analysis of data captured by the Energizer Homepower HP-6 system. It constantly monitors important data from
the utility grid, inverter, and the battery to ensure that optimal system performance is maintained.
The Energizer Homepower HP-6 Series system can operate in 3 unique application modes: Automatic, Semi-
Automatic and Manual. Each mode follows a unique priority and can be customised to operate as per site
requirements.
1. Automatic Mode – is the default mode of operation. The system determines the energy supply requirement
with the priority: Site Loads > Battery Charge > Grid Export > Battery Discharge > Grid Import.
The operating sequence is as follows:
a. Solar generation supplies the connected loads.
b. When site loads are lower than solar generation, excess solar energy is diverted towards charging
the battery.