Commissioning - Energizer HOMEPOWER HP-6S Installation Manual

Table of Contents

Advertisement

7. Commissioning

The Energizer Homepower Installer App requires a mobile device with access to Internet and Bluetooth. The
HP-6M must be used to commission the Energizer Homepower (HP-6M/HP-6S) as shown within the Energizer
Homepower Commissioning Video. energizerhomepower.com/app/installation.
1. Use the Energizer Homepower Installer App to connect your mobile device (either Android/iOS) to
the Energizer Homepower (HP-6M/HP-6S).
2. Verify Address Configuration of all connected units.
3. Follow the prompts within the Energizer Homepower Installer App to connect the Energizer HP-6M
to the internet (using either Wi-Fi, 4G/LTE or Ethernet) and commission the system with the correct
settings.
4. Once communication is established, check the real-time information (infographics) to verify that the
Energizer Homepower (HP-6M/HP-6S) is working correctly.
5. Return the Magna-Flap(s) to its/their original position on Main Unit and Sub Unit(s) if applicable.
Firmware Version, Grid Profile Setting and Power Quality Response
This information is available inside of the Fleet Management System, navigate to a desired plant and view the
values as per below screenshots:
Fig. 37. Firmware Versions
Fig. 38. Grid Profile Settings
Fig. 39. Power Quality Response Mode
NOTE: For compliance with AS/NZS 4777.2:2020 please select from Australia Region A, B,C or
New Zealand. Please contact your local grid operator on which region to select.
V23-00220
6
Energizer Homepower HP-
Series - Installation Manual
36
© Energizer 2022
6
Energizer Homepower HP-
Series - Installation Manual
Fig. 40. Power Response Modes
Power Off Sequence
1. If Backup/UPS loads are connected, turn off respective AC Isolators.
a. If applicable, turn off any AC Isolators connected on the Backup side.
2. Turn off the Main AC Isolator, connected to the Energizer Homepower HP-6 Series system.
a. If applicable, turn off any AC Isolators connected on the grid side.
3. Turn off the Battery Isolators on all connected units as described below:
a. Lift the Magna-Flap on the HP-6M to uncover the Installer Access Panel, housing the Battery Isolator and
the LCD.
b. If HP-6S unit(s) are installed, lift the Magna-Flap to uncover the Installer Access Panel, housing the
Battery Isolator.
c. The Magna-Flaps on the HP-6M (and HP-6S) units will magnetically attach to the metal casing/body of
the unit directly above.
4. Press and hold the ON/OFF Switch on the HP-6M, until a long buzzer noise is heard. Repeat the same for all
connected HP-6S unit(s). At this stage, you have powered off the Energizer Homepower HP-6 Series systems.
5. Return the Magna-Flaps to their original position on the HP-6M and all connected HP-6S units.
DANGER! Although the system is OFF, a certain amount of reserve charge may remain on
the AC/DC terminals. It is recommended to wait 5 mins to ensure full energy discharge.
DANGER! Please do not attempt to disassemble the HP-6M or HP-6S any further, as it may cause
damage to the product or serious human injury. Any further disassembly must be conducted only
by a qualified Energizer service technician to ensure product safety. Unsolicited disassembly
shall void any applicable manufacturer (or performance) Warranty.
V23-00220
37
© Energizer 2022

Advertisement

Table of Contents
loading

This manual is also suitable for:

Homepower hp-6m

Table of Contents