Command:
#CBSn
Values:
Default:
Description:
Command:
#Pn
Values:
Default:
Description:
Command:
#Sx
Values:
Default:
Description:
Command:
#S=x
Values:
Default:
Description:
Multi-Tech Systems, Inc. MultiAccess User Guide
Callback Enable/Disable
n = 0, 1, 2, or 3
0
#CBS0
Disables callback security.
#CBS1
Enables local and remote callback security.
#CBS2
Enables remote callback security only.
#CBS3
Disables callback security until local hang-up or reset.
Set 11-bit Parity
n = 0 or 1
2
#P0 No parity.
#P1 Odd parity.
#P2 Even parity.
Enter Setup Password
x= password (1–8 characters, case sensitive)
MTSMODEM
Enters the callback security setup password.
Store Setup Password
x= password (1–8 characters, case sensitive)
MTSMODEM
Stores a new callback security and remote configuration setup password.
Appendix F – Modem AT Commands