Multitech MultiAccess MA220 User Manual page 68

Analog communications server
Hide thumbs Also See for MultiAccess MA220:
Table of Contents

Advertisement

Appendix F – Modem AT Commands
max_rate
An optional number that specifies the highest rate at which the modem may
establish an upstream (transmit) connection. The value is decimal coded in units of
bps, for example, 33600 specifies the highest rate to be 33600 bps.
0 Maximum rate determined by the modulation selected in mod (default).
300–33600 Maximum rate value limited by the modulation selected in mod. For valid max_rate
values for each mod value, see the following table.
mod value
V92, V90, V34
V32B
V32
V22B
V22, V23C, Bell212A
V21, Bell103
max_rx_rate An optional number that specifies the highest rate at which the modem may
establish a downstream (receive) connection. The value is decimal coded in units
of bps, e.g., 28800 specifies the highest rate to be 28800 bps.
0
Maximum rate determined by the modulation selected in mod (default).
300–56000 Maximum rate value limited by the modulation selected in mod. See "Possible rates" in the
mod table.
Command:
+PCW=n
Values:
Default:
Description:
Command:
+PIG=n
Values:
Default:
Description:
Command:
+PMH=n
Values:
Default:
Description:
68
Call Waiting Enable
n = 0, 1, or 2
2
Controls the action to be taken upon detection of a call waiting tone in V.92 mode.
Values specified by this command are not modified when an AT&F command is
issued.
+PCW=0
Toggles V.24 Circuit 125 and collects Caller ID if enabled by +VCID
+PCW=1
Hangs up
+PCW=2
Ignores V.92 call waiting
+PCW=?
Displays the allowed values
+PCW?
Displays the current value
PCM Upstream Ignore
n = 0 or 1
1
Controls the use of PCM upstream during V.92 operation. PCM upstream allows
faster upload speeds to a V.92 server.
+PIG=0
Disables PCM upstream
+PIG=1
Enables PCM upstream
+PIG=?
Displays the allowed values
+PIG?
Displays the current value
Modem on Hold Enable
n = 0 or 1
1
Controls if modem on hold procedures are enabled during V.92 operation. Normally
controlled by a modem on hold program. Values specified by this command are not
modified when an AT&F command is issued.
+PMH=0
Enables V.92 modem on hold
+PMH=1
Disables V.92 modem on hold
+PMH=?
Displays the allowed values
+PMH?
Displays the current value
Valid max_rate values (bps)
31200, 28800, 26400, 24000, 21600,19200, 16800,
14400, 12000, 9600, 7200, 4800, 2400
19200, 16800, 14400, 12000, 9600, 7200, 4800
14400, 12000, 9600, 7200, 4800
2400
1200
300
Multi-Tech Systems, Inc. MultiAccess User Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multiaccess ma420Multiaccess ma820

Table of Contents