Cornelius VIPER FMFV Installation And Operation Manual page 18

Frozen multi flavour valve
Table of Contents

Advertisement

Put back the face plate
11.
ensure the O-ring and seal are properly
assembled and not damaged
Assemble Hex Nut using adjustable
wrench.
12.
Loosen the grub screws of the valve
assembly using 3/32" Allen key and
reorient the air valve assembly such a
way that, the quick connector should
13.
face towards C-box mounted on viper.
Tighten the grub screw to secure the
position of air valve assembly.
© 2018-19, Cornelius Inc.
Table 5: Installation of Valve
Gasket
Quick
connector
orientation
- 14 -
FMFV - Installation Manual
Figure 19.
Figure 20.
Grub
screw
Figure 21.
Publication Number: 919000012INS
O-ring
FMFV Valve