[Note] This operation stops the alignment plate at the alignment position +5.0mm.
3) Set one sheet of paper [1] in the processing tray unit, fit it to the edge [b] of the rear alignment plate [2], and then measure the
gap [a] between the edge of the front alignment plate [3] and the paper with a scale.
[Note] Since the alignment plate is installed a bit tilting toward the delivery direction, set the paper to be fitted to the edge (on the
delivery side).
4) Enter the gap value measured in the above step 3) in the calculation formula below, enter the calculated adjusted value [a]
and press OK [b].
Adjusted value = gap (mm) x 10 - 50
[Note] Correspondence table of measured gap value and adjusted value
Gap mm (measured value)
adjusted value
2.0
- 30
128