 When the frequency increases, the rotation speed of the compressor increases resulting in an
 When the frequency decreases, the rotation speed of the compressor decreases resulting in a
The following drawing shows a schematic view of the inverter principle:
Inverter Features
The inverter provides the following features:
 The regulating capacity can be changed according to the changes in the outdoor temperature
 Quick heating and quick cooling
 Even during extreme cold weather, high capacity is achieved. It is maintained even when the
 Comfortable air conditioning
 Energy saving heating and cooling
Frequency Limits
The following functions regulate maximum frequency:
Low frequency
 Four way valve operation compensation. Refer to page 100.
High frequency
 Compressor protection function. Refer to page 101.
 Discharge pipe temperature control. Refer to page 102.
 Input current control. Refer to page 103.
 Freeze-up protection control. Refer to page 104.
 Heating peak-cut control. Refer to page 106.
 Defrost control. Refer to page 108.
Forced Cooling
Refer to page 241 for details.
Operation
Part 4 Functions and Control
increase of refrigerant circulation. This leads to a larger amount of heat exchange per unit.
decrease of refrigerant circulation. This leads to a smaller amount of heat exchange per unit.
Amount of heat
exchanged air (large)
Amount of heat
exchanged air (small)
freq=
constant
and cooling/heating load.
The rotation speed of the compressor is increased when starting the heating (cooling).
This enables to reach the set temperature quickly.
outdoor temperature is 2C (35.6°F).
A fine adjustment is integrated to keep the room temperature constant.
Once the set temperature is reached, the energy saving operation enables to maintain the room
temperature at low power.
Refrigerant circulation rate (high)
high speed
high f
low f
low speed
50 Hz
50 Hz
capacity=
freq=variable
60 Hz
60 Hz
variable
Refrigerant circulation rate (low)
Common Functions
Amount of heat exchanged air
(large)
Amount of heat exchanged air
(small)
(R2812)