Daikin 2MXS-W Series Service Manual page 25

Multi-split type air conditioners
Table of Contents

Advertisement

SiUS122226E
1.1.3 Duct Concealed Type
Model
Power Supply
Rated Capacity
Casing Color
Dimensions (H × W × D)
Coil
Type
Rows × Stages × Fin per Inch
Face Area
Fan
Type
Motor Output
Airflow Rate
H / M / L
External Static
Pressure 1
Sound Pressure Level
Sound Power Level
Air Filter 2
Weight (Mass)
Piping
Liquid
Connection
Gas
Drain
Remote
Wired
Controller
Wireless
(Option)
Drawing No.
Notes
Model
Power Supply
Rated Capacity
Casing Color
Dimensions (H × W × D)
Coil
Type
Rows × Stages × Fin per Inch
Face Area
Fan
Type
Motor Output
Airflow Rate
H / M / L
External Static
Pressure 1
Sound Pressure Level
Sound Power Level
Air Filter 2
Weight (Mass)
Piping
Liquid
Connection
Gas
Drain
Remote
Wired
Controller
Wireless
(Option)
Drawing No.
Notes
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Part 2 Specifications
CDMQ07WVJU9
Cooling
Phase
Hz, V
60 Hz, 208 - 230 V
7 kBtu/h Class
in. (mm)
9-5/8 × 27-9/16 × 31-1/2 (245 × 700 × 800)
Cross Fin Coil
3 × 26 × 18
ft² (m²)
1-15/16 (0.178)
Sirocco Fan
HP
cfm
268 / 251 / 230
(m³/min)
(7.6 / 7.1 / 6.5)
inH
O
0.20 (0.60 - 0.12)
2
Pa
50 (150 - 30)
dB(A)
30
dB(A)
44
lbs (kg)
64 (29)
 1/4 (6.4) (Flare)
in. (mm)
 3/8 (9.5) (Flare)
in. (mm)
I.D.  1 (25) / O.D.  1-1/4 (32)
in. (mm)
BRC1E73
BRC082A43
3D141740A
1. External static pressure is changeable in 13 stages by
remote controller. Refer to page 260 for details.
 2. Air filter is not standard accessory, but please mount it
in the duct system of the suction side.
Select its dust collection efficiency (gravity method) 50% or
more.
FDMQ12WVJU9
Cooling
Phase
Hz, V
60 Hz, 208 - 230 V
12 kBtu/h Class
in. (mm)
9-5/8 × 27-9/16 × 31-1/2 (245 × 700 × 800)
Cross Fin Coil
3 × 26 × 18
ft² (m²)
1-15/16 (0.178)
Sirocco Fan
HP
cfm
371 / 318 / 261
(m³/min)
(10.5 / 9.0 / 7.4)
inH
O
0.20 (0.60 - 0.12)
2
Pa
50 (150 - 30)
dB(A)
33
dB(A)
47
lbs (kg)
64 (29)
 1/4 (6.4) (Flare)
in. (mm)
 3/8 (9.5) (Flare)
in. (mm)
I.D.  1 (25) / O.D.  1-1/4 (32)
in. (mm)
BRC1E73
BRC082A43
3D143150
1. External static pressure is changeable in 13 stages by
remote controller. Refer to page 260 for details.
 2. Air filter is not standard accessory, but please mount it
in the duct system of the suction side.
Select its dust collection efficiency (gravity method) 50% or
more.
Heating
1 
0.17
268 / 251 / 230
(7.6 / 7.1 / 6.5)
30
44
1. External static pressure is changeable in 13 stages by
remote controller. Refer to page 260 for details.
 2. Air filter is not standard accessory, but please mount it
in the duct system of the suction side.
Select its dust collection efficiency (gravity method) 50% or
more.
Heating
1 
0.17
371 / 318 / 261
(10.5 / 9.0 / 7.4)
33
47
1. External static pressure is changeable in 11 stages by
remote controller. Refer to page 260 for details.
 2. Air filter is not standard accessory, but please mount it
in the duct system of the suction side.
Select its dust collection efficiency (gravity method) 50% or
more.
Specifications
FDMQ09WVJU9
Cooling
Heating
1 
60 Hz, 208 - 230 V
9 kBtu/h Class
9-5/8 × 27-9/16 × 31-1/2 (245 × 700 × 800)
Cross Fin Coil
3 × 26 × 18
1-15/16 (0.178)
Sirocco Fan
0.17
293 / 265 / 233
293 / 265 / 233
(8.3 / 7.5 / 6.6)
(8.3 / 7.5 / 6.6)
0.20 (0.60 - 0.12)
50 (150 - 30)
32
32
46
46
64 (29)
 1/4 (6.4) (Flare)
 3/8 (9.5) (Flare)
I.D.  1 (25) / O.D.  1-1/4 (32)
BRC1E73
BRC082A43
3D143150
FDMQ15WVJU9
Cooling
Heating
1 
60 Hz, 208 - 230 V
15 kBtu/h Class
9-5/8 × 39-3/8 × 31-1/2 (245 × 1,000 × 800)
Cross Fin Coil
2 × 26 × 18
3-1/8 (0.288)
Sirocco Fan
0.31
448 / 399 / 350
448 / 399 / 350
(12.7 / 11.3 / 9.9)
(12.7 / 11.3 / 9.9)
0.20 (0.60 - 0.20)
50 (150 - 50)
34
34
48
48
77 (35)
 1/4 (6.4) (Flare)
 1/2 (12.7) (Flare)
I.D.  1 (25) / O.D.  1-1/4 (32)
BRC1E73
BRC082A43
3D143151
19