Service Diagnosis; Arc452 Series - Daikin 2MXS-W Series Service Manual

Multi-split type air conditioners
Table of Contents

Advertisement

Service Diagnosis

3. Service Diagnosis

3.1

ARC452 Series

3.1.1 Method 1
1. When TIMER CANCEL button is held down for 5 seconds, 00 is displayed on the temperature
2. Press TIMER CANCEL button repeatedly until a long beep sounds.
 The code indication changes in the sequence shown below.
ARC452A21
Notes
1. A short beep or two consecutive beeps indicate non-corresponding codes.
2. To return to the normal mode, hold TIMER CANCEL button down for 5 seconds. When the
3. Not all the error codes are displayed. When you cannot find the error code, try method 2.
142
display screen.
TIMER CANCEL button
No.
Code
No.
1
00
2
U4
3
L5
4
E6
5
H6
6
H0
7
A6
8
E7
9
U0
10
F3
remote controller is left untouched for 60 seconds, it also returns to the normal mode.
Refer to page 143.
< ARC452 Series >
Code
No.
11
A5
21
12
F6
22
13
C7
23
14
A3
24
15
H8
25
16
H9
26
17
C9
27
18
C4
28
19
C5
29
20
J3
30
SiUS122226E
(R23945)
Code
No.
Code
J6
31
U2
E5
32
EA
A1
33
AH
E1
34
FA
UA
35
H1
UH
36
P9
P4
L3
L4
H7
Part 6 Service Diagnosis

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents