5.1.4 Jumper and Switch Settings
CTXS, FTXS, FVXS series
FTXR series
FVXS series only
on indoor unit
Reference
For the location of the jumper, refer to the following pages.
CTXS, FTXS: page 30
FTXR: page 33
FVXS: page 35
Part 7 Trial Operation and Field Settings
Jumper
on indoor
Function
unit PCB
Fan speed setting when
compressor stops for
JB
thermostat OFF.
(effective only at cooling
operation)
Power failure recovery
function
JC
Jumper
on indoor
Function
unit PCB
Fan speed setting when
compressor stops for
JB
thermostat OFF.
(effective only at cooling
operation)
Power failure recovery
function
JC
Switch
Function
PCB
Upward airflow limit
setting
SW2-4
When connected
(factory setting)
Fan speed setting;
Remote controller setting
Auto-restart
When connected
(factory setting)
The fan stops.
Auto-restart
OFF
(factory setting)
Exposed or half
embedded installation
Field Settings
When cut
The fan stops.
The unit does not
resume operation after
recovering from a power
failure. Timer settings
are cleared.
When cut
Fan speed setting;
Remote controller setting
The unit does not
resume operation after
recovering from a power
failure. Timer settings
are cleared.
ON
Set the switch to ON
position when you install
the indoor unit
embedded in the wall to
avoid condensation.
255