Ffq09/12/15/18W2Vju9 - Daikin 2MXS-W Series Service Manual

Multi-split type air conditioners
Table of Contents

Advertisement

SiUS122226E
1.5

FFQ09/12/15/18W2VJU9

Control PCB
1)
(A1P)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
15)
16)
X30A
DS1
X24A
X18A
X16A
X81A
X17A
X15A
X36A
Part 3 Printed Circuit Board Connector Wiring Diagram
X15A
Connector for float switch
X16A
Connector for room temperature thermistor (suction air thermistor)
X17A, X18A
Connector for indoor heat exchanger thermistor
X20A
Connector for DC fan motor
X24A
Connector for transmitter board
(when the wireless remote controller (option) is used)
X25A
Connector for drain pump motor
X27A
Connector for terminal block (for inter-unit wiring)
X30A
Connector for terminal block (for wired remote controller)
X33A
Connector for adaptor for wiring (option)
X35A
Connector for wiring adaptor for electrical appendices (option)
X36A
Connector for swing motors on decoration panel (option)
X80A
Connector for decoration panel (BYFQ60B3W1) (option)
X81A
Connector for sensor kit (BRYQ60A2W(S)) (option)
HAP
LED for service monitor (green)
DS1
DIP switch for emergency
F1U
Fuse (5A, 250V)
X25A
X33A
HAP
X80A
X20A
X35A
Indoor Unit
F1U
X27A
2P452045-1
39