Dip Switch Definitions
The circuit board is shipped with all DIP switches in the off position. Prior to programming the controller some DIP
switches need to be moved to the ON position. Because each switch serves a specific purpose, please review the
following information, moving the required switches to an ON position. The definitions and purpose are as follows:
NOTE!
DIP switch #3, #4, and #7 MUST be set to the "ON" position for the Iron-OX5 and Sulfur-OX3 filters.
All other switches are set to "OFF."
Switch #
Abbreviation
1
R / T
2
D / I
3
SO / FI
4
- / TCB
5
E / M
6
12 / 24
7
.75" / 1"
8
S / F
Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Definition
Run / Test
Delayed / Immediate
Softener / Filter
Time Clock Back-up Disabled /
Enabled
English / Metric
12 Hour Clock / 24 Hour Clock
3/4" / 1" Control
Standard Refill / Fast Refill
Purpose
Off - Allows controller to function in a normal,
operational mode.
On - Places controller in test mode to verify
operation of the board components &
software.
Off - Reconditioning Cycle will occur at
Delayed Time of Day upon a controller
receiving a valid reconditioning cycle
initiation signal.
On - Reconditioning Cycle shall occur
immediately upon a controller receiving a valid
reconditioning initiation signal, regardless of the
time of day.
Off - The unit shall be operated as a softener.
On -The unit shall function as a filter but
utilize program logic to time the air draw
cycle to recharge the air head.
Off - The time clock backup option is not enabled.
On - Allows the user to program the time
clock function of the control to initiate the
reconditioning cycle on a fixed interval. This
setting MUST be on for the Sulfur-OX3 filter.
Off - The unit will function in standard
English dimensions.
On - The unit will function in standard
metric dimensions.
Off - All time keeping functions shall be
based on an AM/PM basis. The PM icon
shall be lit in the display as appropriate.
On - Time keeping functions shall work on
a 24-hour clock (military time). The AM/PM
display icons will be disabled.
Off - 3/4" Medallist Control Valve
On - 1" Medallist Plus Control Valve
Not applicable for filter applications.
22