Manual Cycling - Culligan Aquasential Select Plus Iron-OX5 Installation, Operation And Service Instructions

Hide thumbs Also See for Aquasential Select Plus Iron-OX5:
Table of Contents

Advertisement

Manual Cycling

Manual Control Cycling
The control can be manually cycled through a reconditioning cycle to troubleshoot the control or verify that the set-up is
complete. When a control is manually cycled back to the service position, the statistical counters of capacity remaining, days
since last reconditioning and the number of reconditionings is in the last 14 days and the life of the unit will not be reset or
updated. If the control is allowed to time out from the last position back to service (Home), the applicable statistical counters
will not be reset or updated. A manual cycling of the control can be accomplished by following the steps as outlined below.
1.
While in the
service mode,
press the "Status"
key until the display
goes blank.
3.
Press and hold
the "Regen" key
for 5 seconds until
the reconditioning
is started. Once
reconditioning is
active, the "Regen"
key will be ignored
until the control
returns to the
service or
"home" position.
4.
The "REG" icon
will flash and the
motor will move
the control to
Backwash position.
While cycling the control, basic diagnostics can be accomplished.
The display shows the "REG" icon solid (if a reconditioning is pending) or flashing (if in reconditioning).
The display will show the current cycle ("H" for service, "1" for Backwash, "2" for Air Draw and "3" for Fast Rinse / Refill)
in the left most segment.
The status of the motor output is to be shown in the 3rd digit from the right. The center bar of the digit will light
solid and the LEDs will turn off when the motor output is on.
The cycle time remaining will be displayed in the two right most end digits.
If a flow meter is attached, the phone icon will show solid and flash if the control is getting a flow signal form the flow meter.
Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Figure 14.
NOTE!
Figure 15.
2.
Press the "+" key to display
the current motor position.
5.
Press the "+" key to cycle to
the next position and remain
there until the cycle times out
or the control is manually indexed.
6.
Continue to press the "+" key until
the control returns to the service
(Home) position. In order to step
through the cycles again, repeat
at step 3.
If the "-" key is pressed at any
time, the control will move back
to the first item in the statistics
menu. Pressing the "+" key from
the statistics menu would move
the display back to the current
diagnostic cycle. The "+" key
will be ignored once the control
returns back to the home position.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquasential select plus sulfur-ox3

Table of Contents