Test Description
Status Key
+ Key
- Key
Regen Key
Home Switch
Position Switch
Flow Meter
Chlorinator
When exiting test mode, if the dip switches or sensors have not changed, the control is to restore all values from
EEPROM, and resume where it left off after homing. If the dip switch or sensors have change, the values should reset
to factory defaults. In either case the valve should home itself upon exit of test mode.
Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Display Information
Display to show "11"
Display to show "12" and motor to run for 15 seconds
Display to show "13" (and turns on Chlorinator
output for 15 seconds IF chlorinator is connected)
Display to show "14"
Display to show "H" when Home switch closed
Display to Blank when open
Display to show "P" when Position switch closed
Display to Blank when open
Display to show "Phone" icon when flow meter is
connected
Display to blink "Phone" icon when flow meter is
sending pulses
Display to show "Colon" icon when chlorinator is
connected
Display to blink "Colon" icon when chlorinator is turned
on
Action Trigger
Press Status Key
Press + Key
Press - Key
Press Regen Key
Close Home Switch
Open Home Switch
Close Position Switch
Open Position Switch
Connect Flow Meter
Spin Flow Meter
Connect Chlorinator
Turn on Chlorinator when the plus
key is pressed.
Circuit Board Troubleshooting
43