Flow Rate
This display will only show if the flow meter is attached to the control. The
display shall show the current flow rate of the water passing through the control.
The display will show "FLO" for two seconds and then the current flow rate
passing through the flow meter until a key is pressed.
This display shall never time out, as opposed to the rest of standard statistics (10
minutes).
Capacity Remaining (gal/ L)
This display will only show if the flow meter is attached to the control.
The display shows the gallons or liters of capacity remaining
in the batch before reconditioning cycle will be triggered. The display
will show "GALr" ("Litr" for metric) for two seconds and then display
the remaining capacity. When reaching "0" the display will remain
at "0" and not show negative values.
This display shall never time out, as opposed
to the rest of standard statistic (10 minutes).
Number of Reconditioning Cycles in Last 14 Days
This display will show the number of reconditioning cycles that have occurred in the last
14 days. The display will first show "14dY" for two seconds and then display the number of
valid reconditioning cycles that have occurred.
Number of Days since Last Reconditioning Cycle
This display shows the number of days that have elapsed since the last reconditioning
cycle. The display will show "dAYS" for two seconds and then the number of days that have
elapsed since the unit completed its last valid reconditioning cycle.
Total Number of Reconditioning Cycles for Life of Unit
This display will show the total number of reconditioning cycles that have occurred
since installation. The display will show "totL" for two seconds and then display the total
number of valid reconditioning cycles for the life of the unit.
Statistical Function Timeout
If no key activity occurs for a period of 600 seconds (10 minutes) while in statistics
functions mode, the mode will time out and return to the time of day display. An
exception is that the flow rate and capacity remaining will not time
out but will remain displayed until a key is pressed. Pressing the "Status" key
at any time will return he unit back to the time display.