2 Safety
Any use of the product other than that described in the Intended Use section does not qualify as appropriate.
The enclosed documentation is an integral part of this product. Keep the documentation in a convenient place for
future reference and observe all instructions contained therein.
Suitable personal protective equipment has to be worn by all persons working on or with the product.
The type label must remain permanently attached to the product.
2.2

Safety Information

This section contains safety information that must be observed at all times when working on or with the product.
To prevent personal injury and property damage and to ensure long-term operation of the product, read this section
carefully and observe all safety information at all times.
Danger to life from electric shock due to live voltage
Danger of electric shock if work is executed incorrectly or under fault conditions. An electric shock can lead to death
or serious injury.
• Disconnect the supply voltage and the measuring cables for the current- and voltage measurement before
performing any work on the Fuel Save Controller.
• Observe the five safety rules when disconnecting the supply voltage:
– Disconnect from voltage sources.
– Ensure that the device cannot be reconnected.
– Ensure that no voltage is present.
– Ground and short-circuit the device.
– Cover and isolate any adjacent live components.
Damage to the PV power plant, gensets or loads due to unauthorized access
Parameters of the Fuel Save Controller can be set incorrectly due to unauthorized access. When parameters are set
incorrectly, technical thresholds are being exceeded. An exceeding of technical thresholds can lead to damage of
the PV power plant, gensets or loads.
• Protect the Fuel Save Controller from unauthorized access.
• Remove the key from the door locks and from the key switch.
• Store the keys in a safe place.
• Ensure that only qualified persons are able to set parameters on the Fuel Save Controller.
• Ensure that access via port forwarding from the external network to the router is deactivated in the
Fuel Save Controller.
Property damage due to dust intrusion and moisture penetration
Dust intrusion or moisture penetration can damage the Fuel Save Controller.
• Protect the Fuel Save Controller against dust and moisture.
• Do not open the Fuel Save Controller at high humidity or high dust levels.
• Close the enclosure after performing any work on the Fuel Save Controller.