‒ Monitor the analyzer status
For more information, see the Atellica VTLI Immunoassay Analyzer Advanced
User Guide.

Test cartridges

The analyzer used disposable cartridges to test patient samples. Each cartridge is for
single use only; never perform a test with a previously used cartridge. For each test, refer
to the instructions for use supplied with the cartridges. The sample material depends on
the test that has to be performed. The sample can be whole blood or plasma. Consult the
instructions for use of the test for the definition of the sample.
Setting up the Atellica VTLi Immunoassay Analyzer

Materials Provided

Atellica VTLi Immunoassay Analyzer

Special Materials Required (Not Provided)

‒ Quality Control Materials

What's in the Box?

Your Atellica VTLi system is contained in a single box, containing:
‒ Analyzer
‒ Docking station
‒ Power cords, AC power supply, Ethernet cable, battery, torx screwdriver
‒ Documentation pack (Users Guide, Quick Reference Guide)
You must order the test cartridges separately.
Installation guidelines
‒ The docking station requires a power connection.
‒ The docking station provides a connection to the local network or directly to a
computer.
‒ A computer is required to install the Service software, which manages the
communication to and from the installed analyzer(s) for configuration and service
purposes, and middleware software, which manages data transfer to the hospital
information system.
‒ Siemens Healthineers recommends using Windows NTP to implement the CT profile.
The service PC should have this solution installed/enabled.
‒ VPN connections are advised for remote service for Siemens Healthineers remote
Service (and middleware software remote service).
Contact your local Siemens Healthineers representative if connection to a laboratory
information system is needed.
The electromagnetic environment should be evaluated prior to operation of the
device. Do not use this device in close proximity to sources of strong electromagnetic
radiation (e.g., unshielded intentional RF sources), as these can interfere with the
proper operation. This equipment complies with the emission and immunity
requirements of the IEC 61326 series.

Unpacking and assembly

Follow these instructions to unpack and assemble the Atellica VTLi Immunoassay Analyzer.
Inspect the box and contents and notify your delivery representative if you notice any
damage or missing items.