In-Rush Current; Cleaning Specifications - ABB Terra 360 CE Operation And Installation Manual

Table of Contents

Advertisement

Technical data
Parameter
MV switch
Automatic circuit breaker
Additional option: Residual current
breaker type B
10.21

In-rush current

Current peaks during the start of a charge session
Parameter
Duration of the current peaks
Maximum current peak (400 VAC and 50/60 Hz)
Parameter
Terra 360
Terra 180
Terra 60
Maximum current peak (480 VAC)
Parameter
Terra 360
Terra 180
Terra 60
10.22

Cleaning specifications

Parameter
Cleaning agent
Non-abrasive tool
128
Function or specification
Dedicated MV/LV transformer for indus-
trial use of the EVSE
For residential use of the EVSE you can
connect directly to low voltage public
grid
Output 4 x 400 A, 690 Vac
Output 4 x 400 A, gG Fuses, 690 Vac
Adjustable Idn 30 to 300 mA
Caution: A
residual
current
breaker
type B is
Mandatory
for an EVSE
with CHA-
deMO out-
put.
Specification [µs]
25
Specification [A]
< 458 duration 1.68 ms
< 458 duration 1.68 ms
< 152 duration 1.5 ms
Specification [A]
< 550 duration 1.68 ms
< 550 duration 1.68 ms
< 183 duration 1.5 ms
Specification
pH value between 6 and 8
Non-woven nylon hand pad
9AKK108467A6398-EN | 002