LoRa Commands
The IWM-LR3 - IWM-LR4 can be controlled over by sending down link commands.
1. Acronims
R2H: Reader To Host H2R: H2R: Host To Reader
Fw: Firmware
Reader: transceiver LoRa
2. List of commands available:
Code
Name
0x07
GET_FW_VERSION
0x0a
Reset
0x14
SET_DATE_AND_TIME
0x15
GET_DATE_AND_TIME
0x16
SET_REVOLUTION_COUNTERS
0x17
GET_REVOLUTION_COUNTERS
0x1A
SET_METER_PAR
0x1B
GET_METER_PAR
0x26
SET_ALARM_PAR
0x27
GET_ALARM_PAR
0x28
GET_ALARM_DATA
0x29
SET_ALARM_DATA
C/R/A field:
Code
0x00
0x01
0x02
IWM-LR3 - IWM-LR4
Description
Read the fw version
Command used to restart the microcontroller that manages the
device
Command used for set data and time
Command used for read data and time
Command used for set the intial consumption of water meter
Command used for read the intial consumption of water meter
Command used to set physical counter parameters
Command used to read the physical parameters of the counter
Command used to set alarm detection parameters
Command used to read alarm detection parameters
Command used to read detected and stored alarm data
Command used to set the flags relating to the detected alarms
Description
C – Command
R - Answer
A – Acknowledge frame