INSTALLATION REQUIREMENTS OPERATION DISPLAY DELIVERY STATUS OPERATING MODE - RADIO ACTIVATION RADIO PARAMETERS DEVICE DISPLAY LOOP ERROR MESSAGE BATTERY AND REPLACEMENT PROCEDURES INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT TRANSLATION TECHNICAL DATA DECLARATION OF CONFORMITY MANUFACTURER ADDRESS HYDRODIGIT-S1 User Manual v1.4.5...
MAP16 U0-D0 ∆P 63 IP68 unit number 2031 Manufacturer Measuring class/Permitted position of installation RxxH: Model horizontal installation RxxV: vertical installation RxxVH: vertical and IR interface horizontal installation End-life Maximum Manufacturer address expiration year admissible pressure HYDRODIGIT-S1 User Manual v1.4.5...
• Storage: from -20°C to +70°C • Operating: from +1°C to +55°C • The storage period must not exceed 1 year • The water meters are precision devices and must be protected from shocks and vibration HYDRODIGIT-S1 User Manual v1.4.5...
For more information visit www.bmeters.com. Dispose of replaced instruments and defective components in accordance with the environmental regulations in force. HYDRODIGIT-S1 User Manual v1.4.5...
Page 7
Install the meter in order to be protected from all impurities and contamination. Remove the old gaskets and clean the sealing surfaces. Grease sealing surfaces (use acid-free, potable water approved grease). The device may only be installed in frost-free areas. HYDRODIGIT-S1 User Manual v1.4.5...
All the versions of the water meter can be installed both horizontally and vertically. For a better performance it is preferable, however, the horizontal installation, with the turbine axis perpendicular to the ground and the reading mechanism facing upwards. HYDRODIGIT-S1 User Manual v1.4.5...
• Transmission frequency: every 200 seconds (current values). • Transmission intervals: every day, from 0 to 24 h. • Encryption: disabled (default). • No historical data. • Transmitted data: volume, actual date and time, reverse flow, alarms. HYDRODIGIT-S1 User Manual v1.4.5...
Page 10
LoRaWAN transmission standard. During this process, the radio icon on the display will blink every second. If the procedure is successful, the icon will remain active and stable, otherwise it will turn off. HYDRODIGIT-S1 User Manual v1.4.5...
Page 11
It is possible to change the configuration parameters into Walk-By mode with an USB to IR interface (B METERS mod. UC-Cable) and the B Metering software: LoRaWAN: • Transmission frequency: every 6 hours (current data) •...
10 seconds Flow: present Radio: activated Firmware version Fu_01_01 (In the “COMBO” version, “Combo 2 seconds 002” will be displayed) 2 seconds Display test “ALL ON” 2 seconds Display test “ALL OFF” 2 seconds Error message HYDRODIGIT-S1 User Manual v1.4.5...
ERROR MESSAGE If an error occurs, an error message is displayed. The error message will be integrated into the device display loop for 2 seconds. Error Type Descrizione Activation Troubleshooting Reset Radio telegram I_ _ _ _ Err Backflow Reverse flow detected, a flow in The error activates after continuous Check water network and the Reset the alarm via LoRa...
Do not expose the battery to an extremely low pressure environment which could cause an explosion or a leak of gases or flammable liquids; Always dispose of batteries in compliance with current regulations; Always use original spare parts authorized by the manufacturer. HYDRODIGIT-S1 User Manual v1.4.5...
For deliveries to countries in the European Economic Area, the operating instructions are to be translated into the appropriate language of user country. Should there be any inconsistencies in the translated text, the original operating instructions (Italian) are to be consulted or the manufacturer should be contacted. HYDRODIGIT-S1 User Manual v1.4.5...
…) where propagation of the radio signal can therefore vary. *** The battery life strongly depends on the working time window, set during the configuration process, and on the environmental conditions. Estimation of the battery life is given by the configuration software. HYDRODIGIT-S1 User Manual v1.4.5...
1. Product type/model: Water Meter – HYDRODIGIT 2. Name and address of the manufacturer: B METERS SRL Via del Friuli, 3 – 33050 GONARS (UDINE) ITALY 3. This declaration of conformity is issued under the sole responsibility of the manufacturer.