HYDRODIGIT
Digital Single Jet water meter
OPERATING INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for B meters HYDRODIGIT

  • Page 1 HYDRODIGIT Digital Single Jet water meter OPERATING INSTRUCTIONS...
  • Page 2: Table Of Contents

    LoRaWAN + Wireless MBUS OMS v4 (COMBO, output configuration LoraWAN + Wireless MBUS OMS v4) . 27 INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT ..............27 TRANSLATION ............................28 TECHNICAL DATA ............................28 DECLARATION OF CONFORMITY ......................29 MANUFACTURER ADDRESS ............................ 30 User Manual v1.4.3 HYDRODIGIT...
  • Page 3: Content

    CONTENT DESIGN According ISO4064 Size (1/2”) (1/2”) (3/4”) D Threading 3/4” 3/4” 1” User Manual v1.4.3 HYDRODIGIT...
  • Page 4: Device Dial

    MAP16 U0-D0 ∆P 63 IP68 unit number 2031 Manufacturer Measuring class/Permitted position of installation RxxH: Model horizontal installation RxxV: vertical installation RxxVH: vertical and IR interface horizontal installation End-life Maximum Manufacturer address expiration year admissible pressure User Manual v1.4.3 HYDRODIGIT...
  • Page 5: Functionality

    FUNCTIONALITY The water meter HYDRODIGIT is a single jet water meter with digital display and inductive rotation detection, anti-magnetic. It is available for both cold and hot water. VERSIONS The device is available in four versions: • Wireless MBUS OMS compatible •...
  • Page 6: Operation

    • Transmission frequency: every 200 seconds (current values). • Transmission span: Every day, from 0 to 24 h. • Encryption: disabled (default). • No historical data. • Transmitted data: Volume, actual date and hour, reverse flow, alarms. User Manual v1.4.3 HYDRODIGIT...
  • Page 7: Wireless Mbus Oms V4 (Combo, Output Configuration Wireless Mbus Oms V4 Only)

    LoRaWAN transmission standard. During this process, the radio icon on the display will blink every second. If the procedure ends well, the icon will remain on and stable, otherwise it will turn off. User Manual v1.4.3 HYDRODIGIT...
  • Page 8: Lorawan + Wireless Mbus Oms V4 (Combo, Output Configuration Lorawan + Wireless Mbus Oms V4)

    • Transmitted data volume, date time, reverse flow, alarms, leakage alarm, fraud alarm (Qmax overflow or backward flow detection). It is possible to change the configuration parameters into Walk-By mode with an USB to IR interface (B METERS mod. UC-Cable) and the B Metering software: LoRaWAN: • Transmission frequency: every 6 hours (current data) •...
  • Page 9: Device Display Loop

    Display test “ALL ON” 2 seconds Display test “ALL OFF” 2 seconds Error message ERROR MESSAGE If an error occurs, an error message is displayed. The error message will be integrated into the device display loop for 2 seconds. User Manual v1.4.3 HYDRODIGIT...
  • Page 10 - Don’t expose the battery to extremely low-pressure environment which could cause an explosion or a loss of flammable gas or liquids; - Always dispose the batteries in compliance with current regulations - Always use original spare parts authorized by the manufacturer. HYDRODIGIT User Manual v1.4.3...
  • Page 11: Protocol Specification

    3: water leak age in the plant (continuous water flow detected) Configuration xx xx xx Encryption code used: field 00 00: no encryption (Signature) x0 05: CBC AES 128 bit (Pre-Shared Key with Cipher Block Chaining) User Manual v1.4.3 HYDRODIGIT...
  • Page 12 (00 00 00 if it did not happen) Date burst dd mm yy Day month year when it was detected that Optional there is burst (00 00 00 if it did not happen) User Manual v1.4.3 HYDRODIGIT...
  • Page 13 VIF is 13, hectolitres if VIF is 14, m3 if VIF-15, 10xm3 if VIF-16) xx xx xx xx Data October-relative reading (HEX, decalitres if Optional VIF is 13, hectolitres if VIF is 14, m3 if VIF-15, 10xm3 if VIF-16) User Manual v1.4.3 HYDRODIGIT...
  • Page 14: Wireless Mbus Oms V4 (Combo, Output Configuration Wireless Mbus Oms V4 Only)

    Generation WMBUS generation Medium 07/06 Medium (water/hot water) ELL data ELL header ELL data CC field ELL data ACC field CI field Control info: shows the next data code Frame counter Progressive count of the frame User Manual v1.4.3 HYDRODIGIT...
  • Page 15 Day month years in which a water leak was detected (00 date 00 00 if it never occurred) Day month years in which a burst was detected (00 00 Burst date ddmmyy 00 if it never occurred) User Manual v1.4.3 HYDRODIGIT...
  • Page 16 VIF is 13, hectoliters if VIF is 14, m3 if VIF is 15) – optional Historical acquisition day (1 – 28 BCD) with a note at xxxxxx Data 0.00. The value 0 indicates the last day of the month with a note at h23.59 User Manual v1.4.3 HYDRODIGIT...
  • Page 17: Lorawan (Combo, Output Configuration Lorawan Only)

    2. Meter installation at a different location (greater distance) with respect to where the JOIN was performed (e.g JOIN completed in the office near the Gateway with SF7 and installation on site few km away where SF12 is required). User Manual v1.4.3 HYDRODIGIT...
  • Page 18: Payload Lorawan

    The temperature is handled with a 2-complement. Negative temperature, for example, will be FF 33 to represent -20.5 ° C. Alarms: Bit 0: Water leak Bit 1: wrong installation Bit 2: Overflow Bit 3: Burst Bit 4: Reverse flow Bit 5: Low battery User Manual v1.4.3 HYDRODIGIT...
  • Page 19: Lorawan Payload Example

    Reverse flow 000086 -> 134 liters Absolute meter counter / reverse flow Alarms 0A è 0000 |1010 so Burst alarm and wrong installation alarm Diameter 0 (DN15); Medium 0 (Water); 0x00CD = 205, so +20,5°C Temperature User Manual v1.4.3 HYDRODIGIT...
  • Page 20: Lorawan Downlink Commands

    R2H: 0x07, 0x00, 0x00, 0x00, 0x00 0x05 H2R: 0x07, 0x01, 0x00, 0x00, 0x05, 0x01, FW1, FW2 GET FW VERSION (0x07) with incorrect length R2H: 0x07, 0x00, 0x00, 0x00, 0x01, 0x00 H2R: 0x07, 0x01, 0x04, 0x00, 0x00 User Manual v1.4.3 HYDRODIGIT...
  • Page 21: Get_Meter_Sn (0X13)

    The Err field can have the following meanings: 0x00 – No error 0x02 – Error on the device type 0x04 – Error on the command length. Example RESET (0x0a) R2H: 0x0a 0x00 0x00 0x00 0x01 0x05 H2R: 0x0a 0x01 0x00 0x00 0x01 0x05 User Manual v1.4.3 HYDRODIGIT...
  • Page 22: Set_Date_And_Time (0X14)

    0x04 – Error on the command length GET_DATE_AND_TIME (0x15) From meter to Application Server: HEADER property Data C/R/A Chain Device type 1 byte 1 byte 1 byte 1 byte 1 byte 1 byte 0x15 0x01 0x05 User Manual v1.4.3 HYDRODIGIT...
  • Page 23: Set_Tx_Par (0X24)

    1 byte 2 byte 0x24 0x00 0x00 0x00 0x03 0x05 0x5460 Answer: HEADER property Data C/R/A Chain Device type 1 byte 1 byte 1 byte 1 byte 1 byte 1 byte 0x24 0x01 0x00 0x00 0x01 0x05 User Manual v1.4.3 HYDRODIGIT...
  • Page 24: Set_Alarm_Par (0X26)

    0x02 – Error on the device type 0x04 – Error on the command length. Example SET_ALARM_PAR (0x26)Temperature bytes enabled R2H: 0x26 0x00 0x00 0x00 0x09 0x05 0x00 0x00 0x00 0x01 0x00 0x00 0x00 0x00 H2R: 0x26 0x01 0x00 0x00 0x00 0x05 User Manual v1.4.3 HYDRODIGIT...
  • Page 25: Get_Alarm_Par (0X27)

    This command is used to read the date of the alarms and flags. From Application server to meter: HEADER property Data C/R/A Chain Device type 1 byte 1 byte 1 byte 1 byte 1 byte 1 byte 0x28 0x00 0x00 0x00 0x01 0x05 User Manual v1.4.3 HYDRODIGIT...
  • Page 26: Set_Alarm_Data (0X29)

    This command is used to set the alarm flags From meter to Application Server: HEADER property Data C/R/A Chain Device type Alarm Flags 1 byte 1 byte 1 byte 1 byte 1 byte 1 byte 2 byte 0x29 0x00 0x00 0x00 0x03 0x05 User Manual v1.4.3 HYDRODIGIT...
  • Page 27: Lorawan + Wireless Mbus Oms V4 (Combo, Output Configuration Lorawan + Wireless Mbus Oms V4)

    The crossed-out wheeled dustbin symbol, on the label on the product, indicates the compliance of this product with the regulations regarding Waste Electrical and Electronic Equipment. Abandonment in the environment or illegal disposal of the product is punishable by law. User Manual v1.4.3 HYDRODIGIT...
  • Page 28: Translation

    Should there be any inconsistencies in the translated text, the original operating instructions (Italian) are to be consulted or the manufacturer should be contacted. TECHNICAL DATA Model HYDRODIGIT Measuring class/Permitted installation R400H, R160V R250H, R160V R160H, R160V...
  • Page 29: Declaration Of Conformity

    1. Product type/model: Water Meter – HYDRODIGIT 2. Name and address of the manufacturer: B METERS SRL Via del Friuli, 3 – 33050 GONARS (UDINE) ITALY 3. This declaration of conformity is issued under the sole responsibility of the manufacturer.
  • Page 30: Manufacturer Address

    MANUFACTURER ADDRESS B METERS srl Via Friuli, 3 • Gonars 33050 (UD) • ITALY Tel: +39 0432 931415 Fax: +39 0432 992661 E-mail (sales/info): info@bmeters.com E-mail (support): ticket@bmeters.com Web: www.bmeters.com User Manual v1.4.3 HYDRODIGIT...