Hide thumbs Also See for HYDRODIGIT-S1:

Advertisement

Quick Links

HYDRODIGIT-S1
User manual v1.7
Index
1. Content .....................................................................2
Design .......................................................................... 2
Device dial ................................................................... 2
Functionality ................................................................ 2
Types ............................................................................ 3
Packing content .......................................................... 3
Safety conditions ........................................................ 3
Envinronmental conditions ........................................ 3
Installation requirements ............................................ 4
2. Function ................................................................... 4
Display .......................................................................... 4
3. Radio parameters .................................................... 5
Delivery status ............................................................ 5
Operating mode - Radio activation ........................... 5
Wireless M-Bus compatible ....................................... 5
Wireless M-Bus OMS v4 ............................................ 5
LoRaWan ...................................................................... 6
LoRaWan + Wireless M-Bus OMS v4 ........................ 6
SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
4. Device display loop ................................................. 6
5. Error message ..........................................................7
8. Technical data ......................................................... 8
Annex A ....................................................................... 9
B METERS srl
Via Friuli, 3
33050 Gonars (UD)
Italy
Tel: +39 0432 931415
Tel: +39 0432 1690412
Fax: +39 0432 992661
Sales/info: info@bmeters.com
Support: ticket@bmeters.com
www.bmeters.com
1

Advertisement

Table of Contents
loading

Summary of Contents for B meters HYDRODIGIT-S1

  • Page 1: Table Of Contents

    HYDRODIGIT-S1 User manual v1.7 B METERS srl Via Friuli, 3 33050 Gonars (UD) Italy Tel: +39 0432 931415 Tel: +39 0432 1690412 Fax: +39 0432 992661 Sales/info: info@bmeters.com Support: ticket@bmeters.com www.bmeters.com Index 1. Content ..............2 4. Device display loop ..........6 Design ................
  • Page 2: Content

    06. Maximum allowed working pressure Functionality The water meter HYDRODIGIT-S1 is a single jet water meter with digital display and rotary induction detection system, antimagnetic. It is available for both hot and cold water. SUBJECT TO CHANGE WITHOUT PRIOR NOTICE...
  • Page 3: Types

    Types The device is available in four versions: → Wireless MBUS OMS compatible → Wireless MBUS OMS v4 (COMBO, output configuration Wireless MBUS OMS v4 only) → LoRaWAN (COMBO, output configuration LoRaWAN only) → LoRaWAN + Wireless MBUS OMS v4 (COMBO, output configuration LoraWAN + Wireless MBUS OMS v4) Packaging content Environmental conditions →...
  • Page 4: Installation Requirements

    If transmission network interfaces are used, especially when cables are routed outside the building, use more protection against electrical interference. In case of danger of frost, empty the system and, if necessary, remove the meter. Rinse the pipes thoroughly before installing the meter. The meter shall be installed in the direction of the arrow on the meter housing, corresponding to the direction of the flow.
  • Page 5: Function

    2. Functioning Display 01. Reverse flow indication (appears if it detects a flow) 02. Main display (m ) decimal position (liters) 03. Units of measurement 04. Historical data 05. Configuration mode 06. End of battery life 07. Radio transmission status 08. Test mode 09. Instantaneous flow rate Note: representation for illustrative purposes only.
  • Page 6: Lorawan

    Transmitted data: volume, reverse flow, diameter, medium, alarms; → Cut-off: disabled*. It is possible to modify some configuration parameters with a USB IR interface (B METERS mod. UC-Cable) and B Metering software: → Transmission frequency: every 6 hours (current values);...
  • Page 7: Error Message

    5. Error messages If an error occurs, an error message is displayed. The error message will be integrated into the display loop of the device for 2 seconds. Reverse flow Reverse flow detected, a flow was detected and alarm via LoRa downlink (if in LoRa version), the counter installation in the opposite direction.
  • Page 8: Information For Correct Disposal Of The Product

    Leaving the equipment in the environment or illegally disposing of it is punishable by law. 8. Technical data Model HYDRODIGIT-S1 R400H, R160V↓→ R250H, R160V↓→ Metrology class/permitted installations R160H, R160V↓→...
  • Page 9: Annex A

    Annex A EU DECLARATION OF CONFORMITY dichiarazione di conformità CE Water meter product type/model: HYDRODIGIT-S1 Modello di contatore per acqua: Name and address of the manufacturer : BMETERS S.r.l. Via del Friuli, 3 – 33050 Gonars (UDINE) ITALY Nome e indirizzo del fabbricante This declaration of conformity is issued under the sole responsibility of the manufacturer.

Table of Contents